Visual and spectrophotometric shade analysis of human teeth.

J Dent Res

Clinic of Fixed and Removable Prosthodontics and Dental Material Sciences, Center for Dental and Oral Medicine, University of Zürich, Plattenstrasse 11, 8028 Zurich, Switzerland.

Published: August 2002

Due to interhuman differences in the perception of color, visual shade assessment of human teeth is lacking standardization that may be improved by the use of a spectrophotometer. In this study, we tested the hypothesis that spectrophotometric assessment of tooth color is comparable with human visual determination. On 30 patients, three operators with unreported visual color deficiency independently selected the best match to the middle third of unrestored maxillary central incisors, using a Vita Classical Shade Guide. The same teeth were measured by means of a reflectance spectrophotometer. In the human group, all 3 visual shade selections matched in only 26.6%. In the spectrophotometric group, all 3 shade selections matched in 83.3%. In 93.3%, Delta E values of visually assessed tooth shades were higher than spectrophotometrically assessed Delta E values (p < 0.0001). The results suggest that spectrophotometric shade analysis is more accurate and more reproducible compared with human shade assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1177/154405910208100815DOI Listing

Publication Analysis

Top Keywords

spectrophotometric shade
8
shade analysis
8
human teeth
8
visual shade
8
shade assessment
8
shade selections
8
selections matched
8
delta values
8
shade
7
visual
5

Similar Publications

Introduction: This in vitro study assessed how shade changes induced by endodontic medicaments affect the transmission of single and multiples wavelengths of infrared light through enamel and dentin.

Methods: Eighteen extracted single-rooted permanent teeth were prepared, removing all extrinsic staining, and cementum. Tooth slices were treated for 4 weeks with UltraCal™ XS, Ledermix™, or were untreated controls.

View Article and Find Full Text PDF
Article Synopsis
  • Speed sintering techniques aim to reduce the sintering time for zirconia ceramics but their effects on multilayer zirconia properties haven't been thoroughly researched.
  • This study evaluates how speed sintering impacts the optical properties and mechanical flexural strength of two types of multilayered zirconia materials (IPS e.max ZirCAD Prime and Esthetic).
  • Results showed that speed sintering significantly decreased flexural strength and affected optical properties like contrast ratio and translucency in various zirconia layers compared to standard sintering methods.
View Article and Find Full Text PDF

Purpose: The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments.

Materials And Methods: For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases.

View Article and Find Full Text PDF

Objectives: To ascertain the degree of precision and repeatability inherent in the "capture to edit" digital imaging system, namely the ColorChecker Passport Photo (X-Rite, MI, USA), and to juxtapose its performance against spectrophotometric assessments utilizing the Vita Easyshade® (Vita Zahnfabrik, H Rauter GmbH & Co. KG., Bad Sackingen, Germany) for the same set of teeth.

View Article and Find Full Text PDF

Purpose: To retrospectively evaluate the long-term clinical, technical, biological, and esthetic outcomes of implant supported single zirconia crowns (ISCs) intraorally cemented to Ti-base hybrid-abutments up to 16 years after placement.

Materials And Methods: A total of 63 ISCs (Xive S, Camlog Screw Line, Replace Select TC NP, Branemark MK II, and 3i Osseotite) were evaluated in 36 patients at two different centers. Original Ti-bases were selected and zirconia meso structures and zirconia crowns were designed using CAD/CAM software and then milled from partially stabilized zirconia blocks.

View Article and Find Full Text PDF