We describe the implementation of the automatic spatial-frequency-selection filter for recognition of patterns obtained with a digital holographic microscope working with a partially coherent source. The microscope provides the complex-optical-amplitude field that allows a refocusing plane-by-plane of the sample under investigation by numerical computation of the optical propagation. By inserting a correlation filter in the propagation equation, the correlation between the filter and the propagated optical field is obtained. In this way, the pattern is located in the direction of the optical axis. Owing to the very weak noise level generated by the partially coherent source, the correlation process is shift invariant. Therefore the samples can be located in the three dimensions. To have a robust recognition process, a generalized version of the automatic spatial-frequency-selection filters has been implemented. The method is experimentally demonstrated in a two-class problem for the recognition of protein crystals.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.41.004108DOI Listing

Publication Analysis

Top Keywords

partially coherent
12
digital holographic
8
holographic microscope
8
microscope working
8
working partially
8
automatic spatial-frequency-selection
8
coherent source
8
correlation filter
8
pattern recognition
4
recognition digital
4

Similar Publications

Rationale: Macular damage is a rare yet significant ocular complication of coronavirus disease 2019 (COVID-19) infection. This report highlights the clinical features, diagnosis, treatment, and outcomes in 2 cases of COVID-19-associated macular damage, contributing to the understanding of its pathophysiology and management.

Patient Concerns: Both patients presented with a sudden onset of visual impairment and black shadows in their central visual fields shortly after contracting COVID-19.

View Article and Find Full Text PDF

The behavior of triple-cation mixed halide perovskite solar cells (PSCs) under ultrashort laser pulse irradiation at varying fluences is investigated, with a focus on local heating effects observed in femtosecond transient absorption (TA) studies. The carrier cooling time constant is found to increase from 230 fs at 2 µJ cm⁻ to 1.3 ps at 2 mJ cm⁻ while the charge population decay accelerates from tens of nanoseconds to the picosecond range within the same fluence range.

View Article and Find Full Text PDF

A co-registration method to validate optical coherence tomography in the breast surgical cavity.

Heliyon

January 2025

BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.

Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.

View Article and Find Full Text PDF

Background: According to the model of the glymphatic system, the directed flow of cerebrospinal fluid (CSF) is a driver of waste clearance from the brain. In sleep, glymphatic transport is enhanced, but it is unclear how it is affected by anesthesia. Animal research indicates partially opposing effects of distinct anesthetics but corresponding results in humans are lacking.

View Article and Find Full Text PDF

We outline two general theoretical techniques to simulate polariton quantum dynamics and optical spectra under the collective coupling regimes described by a Holstein-Tavis-Cummings (HTC) model Hamiltonian. The first one takes advantage of sparsity of the HTC Hamiltonian, which allows one to reduce the cost of acting polariton Hamiltonian onto a state vector to the linear order of the number of states, instead of the quadratic order. The second one is applying the well-known Chebyshev series expansion approach for quantum dynamics propagation and to simulate the polariton dynamics in the HTC system; this approach allows us to use a much larger time step for propagation and only requires a few recursive operations of the polariton Hamiltonian acting on state vectors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!