AI Article Synopsis

  • A nine-locus STR multiplex system called GenePrint PowerPlex 2.1, developed by Promega, was tested alongside the Penta D locus to improve human identification accuracy.
  • The system incorporates highly variable DNA loci and can work with the previously established PowerPlex 1.1 system, sharing some loci for quality control.
  • Validation studies across seven laboratories confirmed the PowerPlex 2.1/Penta D system's efficiency, reproducibility, and reliability for forensic DNA testing, aligning with FBI quality assurance standards.

Article Abstract

In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.

Download full-text PDF

Source

Publication Analysis

Top Keywords

str multiplex
12
powerplex
10
validation studies
8
nine-locus short
8
short tandem
8
tandem repeat
8
repeat str
8
multiplex geneprint
8
geneprint powerplex
8
powerplex system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!