A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a validated capillary electrophoresis method for enantiomeric purity testing of dexchlorpheniramine maleate. | LitMetric

Development of a validated capillary electrophoresis method for enantiomeric purity testing of dexchlorpheniramine maleate.

J Chromatogr A

Department of Pharmaceutical Chemistry and Drug Analysis, Pharmaceutical Institute, Vrije Universiteit Brussel, Belgium.

Published: June 2002

A capillary zone electrophoresis method has been developed for the detection of 0.1% of (R)-levochlorpheniramine maleate in samples of (S)-dexchlorpheniramine maleate. Using 1.5 mM carboxymethyl-beta-cyclodextrin in an acidic background electrolyte, resolution values of more than 10 were obtained. Under these conditions the R-enantiomer is migrating in front of the bulk S-enantiomer. The assay was validated for linearity (2-10 microg/ml; R2 = 0.9992), selectivity [(RS)-pheniramine maleate and (RS)-brompheniramine maleate], limit of detection (0.25 microg/ml), limit of quantification (0.75 microg/ml), analytical precision (intra- and inter-day variability), repeatability of the method (RSD = 5.0%) and accuracy. In samples of dexchlorpheniramine maleate from two different manufacturers, concentrations of, respectively, 0.15% and 1.95% (m/m) of levochlorpheniramine maleate were detected. The method was compared to the HPLC method described in the European Pharmacopoeia III monograph.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(02)00314-xDOI Listing

Publication Analysis

Top Keywords

electrophoresis method
8
dexchlorpheniramine maleate
8
maleate
6
method
5
development validated
4
validated capillary
4
capillary electrophoresis
4
method enantiomeric
4
enantiomeric purity
4
purity testing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!