A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On the selection of optimization parameters for an inverse treatment planning replacement of a forward planning technique for prostate cancer. | LitMetric

The influence of organ volume sampling, lateral scatter inclusion, and the selection of objectives and constraints on the inverse treatment planning process with a commercial treatment planning system is investigated and suitable parameters are identified for an inverse treatment planning replacement of a clinical forward planning technique for prostate cancer. For the beam geometries of the forward technique, a variable set of parameters is used for the calculation of dose from pencil beams. An optimal set is identified after the evaluation of optimized plans that correspond to different sets of pencil-beam parameters. This set along with a single, optimized set of objectives and constraints is used to perform inverse planning on ten randomly selected patients. The acceptability of the resulting plans is verified by comparisons to the clinical ones calculated with the forward techniques. For the particular commercial treatment planning system, the default values of the pencil beam parameters are found adequate for inverse treatment planning. For all ten patients, the optimized, single set of objectives and constraints results in plans with target coverage comparable to that of the forward plans. Furthermore inverse treatment planning reduces the overall mean rectal and bladder doses by 4.8% and 5.8% of the prescription dose respectively. The study indicates that (i) inverse treatment planning results depend implicitly on the sampling of the dose distribution, (ii) inverse treatment planning results depend on the method used by the dose calculation model to account for scatter, and (iii) for certain sites, a single set of optimization parameters can be used for all patient plans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724604PMC
http://dx.doi.org/10.1120/jacmp.v3i3.2563DOI Listing

Publication Analysis

Top Keywords

treatment planning
36
inverse treatment
28
planning
12
objectives constraints
12
treatment
9
optimization parameters
8
inverse
8
planning replacement
8
forward planning
8
planning technique
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!