Problem: How are improvements in productivity in connection with RIS/PACS to be defined? What do they cost? To limit the problem to the relevant topics, we first describe the objectives of a radiology department and the identified bottlenecks in the workflow. How to define and assess the improvements is discussed.

Methods: The case in question for this study is the RIS/PACS project at the "Klinikum der Universität München, Campus Grosshadern". The goals of the project and its present status are reviewed. The project is not yet completed, so this is a "midterm" report.

Results And Discussion: We describe the status of the achieved and not yet achieved goals and of the eliminated bottlenecks. On the plus side, for example, nearly 100% of all digitally generated images (except mammogramms) are digitally archived. They are accessible to the same percentage in radiology via PACS and in the hospital via the webbased intranet image distribution system when needed. In some radiology areas, such as multislice CT, already the reporting can no longer be performed without softcopy image interpretation. However, the full elimination of hardcopy images is still not reality, since the distribution to DICOM viewers for selected requesters with demands for almost reporting quality, high cost image displays is still in the testphase. To reduce film costs, images are being printed on a high resolution paper printer in addition to the intranet distribution during this transition period. On the negative side, due to a lack of job positions in the transcription rooms, about 40% of the reports are still being handwritten by radiologists. Furthermore, the dictated and transcribed reports are usually still not available early enough in the RIS and thereby in the intranet report distribution of the hospital. Here only a speech recognition system can remedy the situation. As soon as this problem is solved and the image distribution to the DICOM viewers works routinely, the reports and the images will be accessible within minutes to maximally within some hours after the examination.

Conclusion: The goals reached so far suffered delays due to unforeseen problems and pitfalls. Altogether, a quieter operation and workflow in radiology has already been achieved, due to less inquiries from the requestors for unfinished examinations, images and/or image copies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00117-002-0718-1DOI Listing

Publication Analysis

Top Keywords

image distribution
8
distribution dicom
8
dicom viewers
8
images
5
image
5
distribution
5
[improving productivity
4
productivity implementing
4
implementing ris
4
ris pacs
4

Similar Publications

Purpose: The loss of synaptic vesicle glycoprotein 2 A (SV2A) can lead to dysfunction of GABAergic neurons, but a direct comparison of SV2A and GABA receptor densities in humans has not been assessed. This study evaluated SV2A and GABA receptor abnormalities in patients with drug-resistant epilepsy (DRE) and compared the patterns to glucose hypometabolism.

Methods: Eleven patients with DRE were retrospectively recruited and underwent PET imaging with [F]fluorodeoxyglucose ([F]FDG), [F]Flumazenil (FMZ), and [F]SynVesT-1.

View Article and Find Full Text PDF

The presence of cancer stem cells is linked to aggressive disease and higher risk of recurrence, and multiple markers have been proposed to detect cancer stem cells. However, a detailed evaluation of the expression patterns and the prognostic value of markers relevant for endometrial cancer is lacking. As organoid models are suggested to be enriched in cancer stem cells, such models may prove valuable to define tissue-specific cancer stem cells.

View Article and Find Full Text PDF

The pursuit of hardware-based security solutions has highlighted the true random number generator (TRNG). Various physical phenomena, from noise generation to quantum physics complexities, have been explored for random number generation. The arc discharge light-induced TRNG (ALTRNG) is introduced, featuring wavelength-dependent photocurrent generation and arc discharge irradiation.

View Article and Find Full Text PDF

Background: In X-ray computed tomography (CT), metal-induced beam hardening artifacts arise from the complex interactions between polychromatic X-ray beams and metallic objects, leading to degraded image quality and impeding accurate diagnosis. A previously proposed metal-induced beam hardening correction (MBHC) method provides a theoretical framework for addressing nonlinear artifacts through mathematical analysis, with its effectiveness demonstrated by numerical simulations and phantom experiments. However, in practical applications, this method relies on precise segmentation of highly attenuating materials and parameter estimations, which limit its ability to fully correct artifacts caused by the intricate interactions between metals and other dense materials, such as bone or teeth.

View Article and Find Full Text PDF

Antibiotic-resistant bacteria often cause lethal infections in both the surficial and deep organs of humans. Failure of antibiotics in resistant infections leads to more effective alternative therapies, like spatiotemporally controllable piezodynamic therapy (PZDT) with deep penetration. Currently, PZDT demands further investigation for improved treatment outcomes and the corresponding therapeutic mechanisms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!