Dynamics of fibrinolysis in a thin layer of a fibrin-agar plate containing streptokinase undergoing the action of the blood plasma enzymes taken from a healthy person was examined. A continuous recording of the area covering the lysis zone was made. The fibrinolysis process on the fibrin-ager plate is shown to proceed uniformly.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dynamics fibrinolysis
8
fibrinolysis thin
8
thin layer
8
[study dynamics
4
layer influence
4
influence streptokinase]
4
streptokinase] dynamics
4
layer fibrin-agar
4
fibrin-agar plate
4
plate streptokinase
4

Similar Publications

Trauma-induced coagulopathy (TIC) is characterized by dynamic changes in fibrinolysis, which can significantly impact patient outcomes. These changes typically manifest in two phases: hyperfibrinolysis followed by fibrinolysis suppression. In the early stages of TIC, there is often an overwhelming release of tissue plasminogen activator, which leads to excessive fibrinolysis.

View Article and Find Full Text PDF

Background: Effective hemorrhage protocols prioritize immediate hemostatic resuscitation to manage hemorrhagic shock. Prehospital resuscitation using blood products, such as whole blood or alternatively dried plasma in its absence, has the potential to improve outcomes in hemorrhagic shock patients. However, integrating blood products into prehospital care poses substantial logistical challenges due to issues with storage, transport, and administration in field environments.

View Article and Find Full Text PDF

Unlabelled: Group A (GAS) is a major human pathogen that causes several invasive diseases including necrotizing fasciitis. The host coagulation cascade initiates fibrin clots to sequester bacteria to prevent dissemination into deeper tissues. GAS, especially skin-tropic bacterial strains, utilize specific virulence factors, plasminogen binding M-protein (PAM) and streptokinase (SK), to manipulate hemostasis and activate plasminogen to cause fibrinolysis and fibrin clot escape.

View Article and Find Full Text PDF

Blood-contacting medical devices, especially extracorporeal membrane oxygenators (ECMOs), are highly susceptible to surface-induced coagulation because of their extensive surface area. This can compromise device functionality and lead to life-threatening complications. High doses of anticoagulants, combined with anti-thrombogenic surface coatings, are typically employed to mitigate this risk, but such treatment can lead to hemorrhagic complications.

View Article and Find Full Text PDF

Purpose: Trauma-associated coagulopathy has been considered to develop as a result of increased fibrinolysis due to massive bleeding, tissue damage and hypoperfusion. However, it has not been investigated whether hematoma may cause trauma-associated coagulopathy. Using experimental animal model, we analyzed the effects of hematoma formation on coagulation and fibrinolysis parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!