A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Excitation pulse deconvolution in luminescence lifetime analysis for oxygen measurements in vivo. | LitMetric

Oxygen-dependent quenching of phosphorescence has been proven to be a valuable tool for the measurement of oxygen concentrations both in vitro and in vivo. For biological measurements the relatively long lifetimes of phosphorescence have promoted time-domain-based devices using xenon arc flashlamps as the most common excitation light source. The resulting complex form of the excitation pulse leads to complications in the analysis of phosphorescence lifetimes and ultimately to errors in the recovered pO2 values. Although the problem has been recognized, the consequences on in vivo phosphorescence lifetime measurements have been neglected so far. In this study, the consequences of finite excitation flash duration are analyzed using computer simulations, and a method for the recovery of phosphorescence decay times from complex photometric signals is presented. The analysis provides an explanation as to why different calibration constants are reported in the literature and presents a unified explanation whereby calibration constants are not solely a property of the dye but also of the measuring device. It is concluded that complex excitation pulse patterns without appropriate analysis methods lead to device-specific calibration constants and nonlinearity and can be a potent source of errors when applied in vivo. The method of analysis presented in this article allows reliable phosphorescence lifetime measurements to be made for oxygen pressure measurements and can easily be applied to existing phosphorimeters.

Download full-text PDF

Source
http://dx.doi.org/10.1562/0031-8655(2002)076<0012:epdill>2.0.co;2DOI Listing

Publication Analysis

Top Keywords

excitation pulse
12
calibration constants
12
phosphorescence lifetime
8
lifetime measurements
8
explanation calibration
8
phosphorescence
6
excitation
5
analysis
5
measurements
5
pulse deconvolution
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!