A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a novel, bioluminescence-based, fungal bioassay for toxicity testing. | LitMetric

Development of a novel, bioluminescence-based, fungal bioassay for toxicity testing.

Environ Microbiol

Department of Plant and Soil Science, University of Aberdeen, Cruickshank Building, St. Machar Drive, Aberdeen AB24 3UU, UK.

Published: July 2002

Naturally bioluminescent fungi, Armillaria mellea and Mycena citricolor, were used to develop a novel, bioluminescence-based bioassay for toxicity testing. Bioassays were carried out to assess the toxicity of 3,5-dichlorophenol (3,5-DCP), pentachlorophenol (PCP), copper and zinc. The results suggested that 60 min was a suitable exposure time for the bioassay. Light reduction was observed in response to 3,5-DCP, PCP and Cu for both A. mellea and M. citricolor, but to Zn only for A. mellea. Armillaria mellea was significantly less sensitive to 3,5-DCP and PCP than M. citricolor. The EC50 values for A. mellea and M. citricolor were similar to EC50 values for 3,5-DCP, PCP and Cu (but not Zn) of bioluminescence-based bacterial biosensors. They were also similar to EC50 values for Cu and Zn of a bioluminescence-based yeast biosensor. The results highlighted the importance of using both prokaryotic and eukaryotic biosensors. The novel bioassay provides a rapid and sensitive method to assess bioavailability of pollutants as well as a method to determine their toxicity to filamentous fungi. It also expands the range of organisms that can be used for bioluminescence-based toxicity testing by complementing existing biosensors.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1462-2920.2002.00315.xDOI Listing

Publication Analysis

Top Keywords

toxicity testing
12
35-dcp pcp
12
ec50 values
12
novel bioluminescence-based
8
bioassay toxicity
8
armillaria mellea
8
mellea citricolor
8
citricolor ec50
8
bioluminescence-based
5
toxicity
5

Similar Publications