We produced a new monoclonal antibody (mAb) to the excretory-secretory (ES) antigens of Toxocara canis larvae. The mAb (IgG1) reacts specifically with the 120 kDa protein of many ES molecules and does not have any cross-reactivity with adult T. canis antigens. Sandwich ELISA to detect the ES antigens was performed using the mAb and rabbit polyclonal antiserum. The lower limit for the detection of ES antigen was 4 ng/ml; assay was proportional within a concentration range of 4 ng/ml to 1 microg/ml of ES antigen. This assay system may prove valuable when seeking to quantify parasite burden early in infection and when determining the efficacy of anthelmintic treatment.

Download full-text PDF

Source

Publication Analysis

Top Keywords

sandwich elisa
8
excretory-secretory antigens
8
antigens toxocara
8
toxocara canis
8
canis larvae
8
monoclonal antibody
8
elisa detection
4
detection excretory-secretory
4
antigens
4
larvae specific
4

Similar Publications

Glycan-Matchmade Multivalent Decoration of Enzyme Labels for Amplified Electrochemical Detection of Glycoproteins.

Anal Chem

January 2025

Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China.

Glycoproteins are of significant value to liquid biopsy of human diseases. Herein, we present a universal electrochemical platform for the amplified detection of glycoproteins, taking advantage of the glycan-matchmade multivalent decoration of enzyme labels for the enzymatic signal amplification. Briefly, the glycan-matchmade multivalent decoration involves two steps, i.

View Article and Find Full Text PDF

Statement Of Problem: Clinical studies evaluating the levels of interleukin-1 beta (IL-1β) in tears and conjunctival secretions of patients with ocular defects after using ocular prostheses are lacking. Therefore, a comparative evaluation of IL-1β levels in the defective eye before and after placement of an ocular prosthesis is needed.

Purpose: The purpose of this clinical study was to compare the microbiota and IL-1β in tears and conjunctival secretions of patients with an ocular defect after using an ocular prosthesis.

View Article and Find Full Text PDF

High-affinity VNARs targeting human hemoglobin: Screening, stability and binding analysis.

Int J Biol Macromol

January 2025

College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China. Electronic address:

Hemoglobin, composed of α- and β-chains, is essential for oxygen transport and is key in diagnosing and treating gastrointestinal and blood disorders. It also aids in detecting blood contamination and estimating transfusion volumes. Immunological methods, based on antigen-antibody interactions, are distinguished by their high sensitivity and accuracy.

View Article and Find Full Text PDF

Microfluidic Integration of Magnetically Functionalized Microwires for Flow Cytometry Protein Quantification.

Materials (Basel)

January 2025

Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada.

A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are injected inside microfluidic channels and immobilized magnetically on the surface of glass-coated soft magnetic microwires placed along the symmetry axis of these channels. A fluorescent (Cy5) immunomagnetic sandwich ELISA is then performed by sequentially flowing the sample and all necessary reagents in the microfluidic channels.

View Article and Find Full Text PDF

An obstacle for many microfluidic developments is the fabrication of its structures, which is often complex, time-consuming, and expensive. Additive manufacturing can help to reduce these barriers. This study investigated whether the results of a microfluidic assay for the detection of the promyelocytic leukemia (PML)-retinoic acid receptor α (RARα) fusion protein (PML::RARA), and thus for the differential diagnosis of acute promyelocytic leukemia (APL), could be transferred from borosilicate glass microfluidic structures to additively manufactured fluidics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!