Rationale: Previous studies have shown that an increase in inspiratory pressure during nasal intermittent positive pressure ventilation (IPPV) does not result in increased effective minute ventilation (E) due to glottic interference.
Study Objectives: To test the consequences of increases in negative pressure ventilation (NPV) on V(E).
Material And Methods: Eight healthy awake subjects underwent NPV delivered by an iron lung. First, NPV was started at a respirator frequency (f) of 15 cycles per minute with an inspiratory negative pressure (INP) of - 15 cm H(2)O (F15-P15). Then, f was increased to 20 cycles per minute and INP was kept at - 15 cm H(2)O. Next, f was kept at 20 cycles per minute and INP was reduced to - 30 cm H(2)O (F20-P30). Finally, f was decreased to 15 cycles per minute and INP was kept at - 30 cm H(2)O. At each step and for each breath, effective tidal volume (VT), V(E), and end-tidal carbon dioxide pressure were measured. In three subjects, the glottis width was assessed using fiberoptic bronchoscopy.
Results: From spontaneous breathing to the first step of NPV (F15-P15), we observed an inhibition of the phasic inspiratory diaphragmatic electromyogram concomitant to a significant increase in V(E) (p < 0.0005). For the group as a whole, the increase in mechanical ventilation (from F15-P15 to F20-P30) resulted in significant increases in VT and V(E) leading to hypocapnia (p < 0.0005). Moreover, the glottis width did not decrease with the increase in mechanical ventilation.
Conclusions: We conclude that in normal awake subjects, NPV allowed a significant increase in V(E). These results differ from those previously obtained with nasal IPPV in which the glottic width interferes with the delivered mechanical ventilation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1378/chest.122.1.99 | DOI Listing |
Appl Physiol Nutr Metab
January 2025
University of Saskatchewan, Saskatoon, Saskatchewan, Canada;
We compared stretching, isometrics, and aerobic exercise for effectiveness in decreasing blood pressure post-exercise. Using a randomized crossover design, 5 males and 4 females (21.3y; normotensive) participated in four 30-minute sessions on separate days: static stretching (30s stretches, major muscle groups), isometric exercise, aerobic cycling (75% VO2peak), and control (rest), with blood pressure and heart rate measured before exercise (or rest) and for 60 minutes post-exercise (or rest).
View Article and Find Full Text PDFIn image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.
View Article and Find Full Text PDFThis work aimed at addressing the problem of hexavalent chromium pollution in the water environment, designing and preparing the Cu/CuO/NH-MIL-88B (Fe) heterojunction material with NH-MIL-88B (Fe) as the carrier, Cu/CuO was loaded on NH-MIL-88B (Fe) by light-assisted reduction. The loading of CuO effectively improves the visible light absorption capacity of the composite material. The SPR effect of Cu improves the separation and transfer of photogenerated carriers in the composite material.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Department for Psychosomatic Medicine and Psychotherapy, Universitatsklinikum Jena, Philosophenweg 3, Jena, Thüringen, 07743, GERMANY.
Heart rate variability (HRV) is an important indicator of cardiac autonomic function. Given its clinical significance, reliable HRV assessment is crucial. Here, we assessed test-retest stability, as a key aspect of reliability, quantifying the consistency of a measure when repeated under the same conditions.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Key Laboratory of Intelligent Supramolecular Chemistry at the University of Yunnan Province, National and Local Joint Engineering Research Center for Green Preparation Technology of Biobased Materials, School of Chemistry & Environment, Yunnan Minzu University, Kunming 650500, P. R. China.
Developing efficient and recyclable iodine adsorbents is crucial for addressing radioactive iodine pollution. An imidazole cation-bridged pillar[5]arene polymer (P5-P5I) was synthesized via a salt formation reaction. P5-P5I exhibited a high iodine vapor capture capacity of 2130.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!