A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inductively coupled plasma mass spectrometric determination of molybdenum in urine. | LitMetric

Inductively coupled plasma mass spectrometric determination of molybdenum in urine.

Rapid Commun Mass Spectrom

Laboratory of Environmental Hygiene and Industrial Toxicology, Salvatore Maugeri Foundation, via Ferrata 8, 27100 Pavia, Italy.

Published: August 2002

A method was developed for the determination of molybdenum (Mo) in human urine by direct dilution of the sample in doubly distilled water with 1% HNO3 (v/v) and inductively coupled mass spectrometry (ICP-MS). In and Y were used as internal standards. Since (98)Mo provides a higher sensitivity, it was chosen as the reference isotope. The influence of different factors, such as sample dilution, HNO3 concentration and the stability of the analyte were evaluated. The detection limit (LOD) was assessed at 0.2 microg/L Mo, while the lower limit of quantification (LOQ) was 0.6 microg/L. Recoveries ranged between 97.2 and 100.7% from solutions containing from 10 to 50 microg/L Mo. Linear calibration curves were generated from 2.1 and 52.1 microg/L with coefficients of variation (CV ) ranging from 1.62 to 3.56%. In order to establish reference values (RV) for molybdenum, the procedure presented here was used to determine Mo in the urine of a population group living in Tuscany, Italy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.720DOI Listing

Publication Analysis

Top Keywords

inductively coupled
8
determination molybdenum
8
coupled plasma
4
plasma mass
4
mass spectrometric
4
spectrometric determination
4
molybdenum urine
4
urine method
4
method developed
4
developed determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!