A quantitative dual-isotope single-photon emission tomography (SPET) technique for the assessment of lung ventilation (V) and perfusion (Q) using, respectively, technetium-99m labelled Technegas (140 keV) and indium-113m labelled macro-aggregated albumin (392 keV), is presented, validated and clinically tested in a healthy volunteer. In order to assess V, Q and V/Q distributions in quantitative terms, algorithms which correct for down scattering, photon scattering and attenuation, as well as an organ outline algorithm, were implemented. Scatter and down-scatter correction were made in the spatial domain by pixel-wise image subtraction of projection-dependent global scattering factors obtained from the energy domain. The attenuation correction was based on an iterative projection/back-projection method. All studies were made on a three-headed SPET system (Trionix) with medium-energy parallel-hole collimators. The set of input data for quantification was based on SPET acquisition of emission data in four separate energy windows, the associated cumulative energy spectra and transmission data. The attenuation correction routine as well as the edge detection algorithm utilized data from (99m)Tc transmission tomography. Attenuation data for (113m)In were obtained by linear scaling of the (99m)Tc attenuation maps. The correction algorithms were experimentally validated with a stack phantom system and applied on a healthy volunteer. The mean difference between the corrected SPET data of the dense stack lung phantom and those obtained from the corresponding scatter- and attenuation-"free" version was only 1.9% for (99m)Tc and 0.9% for (113m)In. The estimated fractional V/Q distribution in the 3-D lung phantom volume had its peak at V/Q=1, with a width (FWHM) of 0.31 due to noise, particularly in the (113m)In images, and to partial volume effects. For a healthy volunteer, the corresponding values were 0.9 and 0.35, respectively. This method allows accurate assessment of radionuclide distribution on a regional basis. For basic lung physiology and clinical practice, the method allows assessment of the global frequency functions of the V, Q and V/Q distributions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-002-0803-8 | DOI Listing |
J Am Podiatr Med Assoc
January 2025
†Medical Point Gaziantep Hospital, Gaziantep, Turkey.
Background: The incidence of diabetic foot infections is increasing due to the rising number of persons with diabetes and the prolonged life expectancy. It is vital to differentiate soft-tissue infection (STI) from diabetic foot osteomyelitis (DFO), as treatment modalities and durations vary widely, but this can be challenging. We aimed to assess the blood concentration levels of the high mobility group box 1 protein (HMGB-1) in STI and DFO compared to healthy subjects, and to investigate whether this protein could contribute to differentiating STI from DFO.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine (Shenzhen Traditional Chinese Medicine Hospital), Shenzhen, China.
Background: Multifrequency MR elastography (mMRE) enables noninvasive quantification of renal stiffness in patients with chronic kidney disease (CKD). Manual segmentation of the kidneys on mMRE is time-consuming and prone to increased interobserver variability.
Purpose: To evaluate the performance of mMRE combined with automatic segmentation in assessing CKD severity.
Ir J Med Sci
January 2025
Department of Urology, Başkent University Alanya Application and Research Center, Antalya, Türkiye.
Background: Inflammatory bowel disease (IBD) is a chronic disease that includes Crohn's disease and ulcerative colitis. Studies found that 40-60% of women diagnosed with IBD have sexual dysfunction (SD).
Aims: To determine SD and associated factors in women with IBD.
Surg Radiol Anat
January 2025
Anatomy Department, University of Western Brittany (UBO), Brest, France.
Purpose: The aim was to establish a functional MRI protocol for analyzing human stereoscopic vision in clinical practice. The feasibility was established in a cohort of 9 healthy subjects to determine the functional cortical areas responsible for virtually relief vision.
Methods: Nine healthy right-handed subjects underwent orthoptic examination and functional MRI.
Biosci Rep
January 2025
Uniwersytet Medyczny im Karola Marcinkowskiego w Poznaniu, Poznan, Poland.
Roughly 90% of the Polish population experiences vitamin D deficiency. The 3-epi-25(OH)D2 and 3-epi-25(OH)D3 are stereoisomers of 25(OH)D2 and 25(OH)D3, and they can inadvertently be included in measurements of 25(OH)D levels, potentially leading to its overestimating. We aimed to measure 25(OH)D2 and 25(OH)D3, their epimers 3-epi-25(OH)D2 and 3-epi-25(OH)D3, and biologically active 1,25(OH)2D3 in patients with cardiovascular disease and healthy volunteers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!