Two different analytical methods for the quality control of fluoxetine in commercial formulations have been developed and compared: a spectrofluorimetric method and a capillary zone electrophoretic (CZE) method. The fluorescence emission values were measured at lambda=293 nm when exciting at lambda=230 nm. The CZE method used an uncoated fused-silica capillary and pH 2.5 phosphate buffer as the background electrolyte. The extraction of fluoxetine from the capsules consisted of a simple one-step dissolution with methanol/water, filtration and dilution. Both methods gave satisfactory results in terms of precision; the best results were obtained for the electrophoretic method, with RSD% values always lower than 2.0%. The accuracy was assessed by means of recovery studies, which gave very good results, between 97.5 and 102.6%. Furthermore, both methods also have the advantage of being very rapid.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0731-7085(02)00154-1 | DOI Listing |
Talanta
January 2025
DSM-Firmenich, Kogle Allé 4, 2970, Hørsholm, Denmark.
The development and validation of an accurate, selective, and eco-friendly capillary zone electrophoretic detection (CZE) method has been presented for concurrent measurement of inorganic and organic anions including chloride, sulfate, formic acid, citric acid, acetic acid, phosphate, and glutamic acid in Human Milk Oligosaccharides (HMOs) for the first time. An electrolyte composed of an aqueous solution of benzoic acid, 16.38 mM; l-histidine, 24.
View Article and Find Full Text PDFObes Surg
January 2025
Nederlandse Obesitas Kliniek, 2591 XR, The Hague & Gouda, The Netherlands.
Purpose: Patient-reported outcomes are important as obesity is a chronic disease with a substantial impact. A multidisciplinary task force selected six scales (48 questions) from the validated BODY-Q questionnaire. This subset was gradually introduced and evaluated in a mandatory nationwide registry.
View Article and Find Full Text PDFPharmeur Bio Sci Notes
December 2024
European Directorate for the Quality of Medicines & HealthCare, Department of Biological Standardisation, OMCL Network & HealthCare (DBO), Council of Europe, Strasbourg, France.
Here we report the outcome of a collaborative study aimed at demonstrating the suitability of the candidate Chemical Reference Substance (CRS) as a replacement reference (batch 2) for the physicochemical methods in European Pharmacopoeia monograph . Results from the study demonstrated that for the physicochemical methods described in the monograph - capillary zone electrophoresis, polyacrylamide gel electrophoresis and immunoblotting, peptide mapping and glycan mapping - the candidate CRS is essentially identical to CRS batch 1 and is suitable to be established as Erythropoietin for physicochemical tests CRS batch 2. CRS batch 2 is a freeze-dried preparation presented in vials.
View Article and Find Full Text PDFInt J Mol Sci
November 2024
Department of Laboratory Medicine, Chang Gung Memorial Hospital, Linkou Main Branch, Taoyuan City 333, Taiwan.
Capillary zone electrophoresis-immunosubtraction (CZE-IS) is an essential laboratory test in diagnosing plasma cell neoplasms. However, the current interpretation of the test results is subjective. To evaluate CZE-IS in a more precise manner, this study proposed five key indexes, namely sharpness index, light chain index, immunoglobulin G index, immunoglobulin A index, and immunoglobulin M index.
View Article and Find Full Text PDFJ Sep Sci
November 2024
Chemistry Department, Grupo de Química Analítica e Quimiometria (GQAQ), Institute of Exact Sciences, Federal University of Juiz de Fora (UFJF), Juiz de Fora, Brazil.
Novel methods were proposed for determining primaquine (PQN) in tablets by multiple-injection capillary zone electrophoresis (MI-CZE) and by short-end injection CZE (SEI-CZE), both with ultraviolet detection. The background electrolyte (BGE), consisting of 20 mmol/L of tris (hydroxymethyl) aminomethane and 30 mmol/L of hydrochloric acid at pH 2.0, was selected considering a comprehensive study involving the effective mobility versus pH curves of the analytes and BGE components.