Purpose: To evaluate the uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses (IOLs) in eyes with uveitis.

Setting: Department of Ophthalmology, University of Vienna, Vienna, Austria.

Methods: This prospective study comprised 72 eyes with uveitis and 68 control eyes having phacoemulsification and IOL implantation by 1 surgeon. Patients received 1 of the following IOLs: foldable hydrophilic acrylic (Hydroview, Bausch & Lomb), hydrophobic acrylic (AcrySof, Alcon), or silicone (CeeOn 911, Pharmacia). Postoperative evaluations were at 1, 3, and 7 days and 1, 3, and 6 months. Cell reaction was evaluated by specular microscopy of the anterior IOL surface and the anterior and posterior capsule reaction, by biomicroscopy.

Results: Small round cell deposition was observed on all IOLs in the immediate postoperative period, especially in eyes with uveitis. This reaction decreased 3 to 6 months after surgery. Although the CeeOn 911 had a higher mean grade of small cells, there was no statistical difference between the 3 IOL types after 6 months in the uveitis and control groups. Foreign-body giant cells (FBGCs) increased after 1 week to 1 month. The AcrySof IOLs had the highest number of FBGCs; after 6 months, there was a statistically significant difference between the AcrySof and Hydroview uveitis groups (P =.036) and the AcrySof and CeeOn 911 uveitis groups (P =.003) but there was no difference among the 3 IOL types in the control group. Lens epithelial cell outgrowth persisted on the Hydroview IOLs in control eyes and regressed on all 3 IOL types in uveitic eyes and on the AcrySof and CeeOn 911 IOLs in control eyes (P =.0001). Anterior capsule opacification (ACO) was more severe on all IOL types in uveitic eyes and on the CeeOn 911 IOL in control eyes. Posterior capsule opacification (PCO) was more severe in uveitic eyes. The Hydroview group had more severe PCO than the AcrySof and the CeeOn 911 groups in uveitis and control eyes. Six months postoperatively, the difference was significant (P =.0001). There was no significant difference between the AcrySof and CeeOn 911 IOLs.

Conclusions: Intraocular lens biocompatibility is inversely related to inflammation. Hydrophilic acrylic material had good uveal but worse capsular biocompatibility. Hydrophobic acrylic material had lower uveal but better capsular biocompatibility. Silicone showed a higher small cell count (mild) and more severe ACO but achieved PCO results comparable to FBGC results and better than those with the AcrySof lens 6 months after surgery. Despite the differences in IOL biocompatibility, all patients benefited from the surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(02)01425-6DOI Listing

Publication Analysis

Top Keywords

ceeon 911
28
control eyes
20
hydrophilic acrylic
16
hydrophobic acrylic
16
uveitic eyes
16
iol types
16
acrysof ceeon
16
eyes
12
capsular biocompatibility
12
uveitis control
12

Similar Publications

Purpose: To evaluate the long-term uveal and capsular biocompatibility of 5 intraocular lenses (IOLs) in eyes with uveitic cataract.

Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

Design: Comparative case series.

View Article and Find Full Text PDF

Purpose: To evaluate the uveal and capsular biocompatibility of 3 types of sharp-edged foldable intraocular lenses (IOLs) in eyes with pseudoexfoliation syndrome (PEX).

Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

Methods: Eighty-five eyes with PEX had implantation of 1 of the following sharp-edged 3-piece IOLs: hydrophilic acrylic (Injectacryl F3000, OphthalMed), hydrophobic acrylic (AcrySof MA60MB, Alcon), or silicone (CeeOn 911, AMO).

View Article and Find Full Text PDF

Purpose: To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL.

Setting: Bretonneau University Hospital, Tours, France.

Methods: Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO).

View Article and Find Full Text PDF

Purpose: To study optical aberrations in eyes having uneventful cataract surgery and in-the-bag implantation of an aspherical Tecnis Z9000 intraocular lens (IOL) (AMO) or a spherical CeeOn Edge 911 IOL (Pharmacia) and compare the results with those in a group of phakic age-matched eyes.

Setting: Ophthalmic Unit, Hospital and University of Verona, Verona, Italy.

Materials: Three groups, each with 30 patients (30 eyes), were examined with the Topcon KR-9000PW topographer/aberrometer.

View Article and Find Full Text PDF

Purpose: To assess the quality of vision in pseudophakic patients with a prolate aspherical intraocular lens (IOL) compared to patients with a spherical IOL.

Patients And Methods: Twenty patients undergoing cataract surgery were divided into two groups according to the type of IOL: ten prolate aspherical IOLs (TECNIS Z9000, AMO, USA) and ten spherical IOLs (911 CeeOn Edge, AMO, USA). The integrity of ocular functions was assessed with clinical examination and multifocal electroretinogram.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!