A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses. | LitMetric

Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses.

J Cataract Refract Surg

Department of Ophthalmology and Visual Sciences, University of Utah Health Sciences Center, Salt Lake City, Utah 84132, USA.

Published: July 2002

Purpose: To compare the 3-year performance of the 3-piece AcrySof (Alcon) and the SI-40 silicone (Allergan) intraocular lenses (IOLs).

Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.

Methods: In this retrospective study, patients with no complications and at least a 3-year follow-up after IOL implantation were examined for signs of inflammation, visual function, posterior capsule opacification (PCO), and satisfaction.

Results: One hundred eleven patients were enrolled with equivalent visual acuity, inflammation, and PCO parameters. The AcrySof eyes had less anterior capsule opacification and more intralenticular inclusions than the other group. Complete anterior capsule overlap was associated with decreased PCO, and significantly more SI-40 eyes had complete anterior capsule overlap.

Conclusions: The second-generation silicone IOL was equivalent to the 3-piece AcrySof in patient satisfaction, visual function, inflammation, and PCO. The amount of anterior capsule overlap on the IOL may help to explain the study differences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(02)01460-8DOI Listing

Publication Analysis

Top Keywords

anterior capsule
16
3-piece acrysof
12
si-40 silicone
8
intraocular lenses
8
visual function
8
capsule opacification
8
inflammation pco
8
complete anterior
8
capsule overlap
8
capsule
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!