Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The study assessed clinical outcomes of closure device use following percutaneous coronary revascularization using current standards of anticoagulation and antiplatelet therapy.
Background: Evaluation of the outcomes of patients by use of vascular closure devices during coronary interventions employing current standards of anticoagulation and glycoprotein (GP) IIb/IIIa inhibitor therapy is limited.
Methods: We evaluated outcomes of 4,525 consecutive patients who underwent percutaneous coronary intervention between July 1997 and April 2000. All patients received anticoagulation with heparin and GP IIb/IIIa inhibitor therapy with abciximab. The closure method was manual in 1,824 patients, Angioseal in 524 patients and Perclose in 2,177 patients. Procedural and hospital vascular outcomes were evaluated.
Results: Closure device success was 97.1% Angioseal and 94.1% Perclose (p < 0.05). Minor vascular complications occurred in 1.8% of manual patients, 1.1% of Angioseal patients and 1.2% of Perclose patients (p = NS); major complications occurred in 1.3% of manual patients, 1.1% of Angioseal patients and 1.0% of Perclose patients (p = NS). Multivariate logistic regression identified only closure device failure as an independent predictor of a vascular complication. In patients with successful closure with a device, minor complications (0.8% vs. 1.8%, p < 0.05) and any complication (1.5% vs. 2.5%, p < 0.05) were reduced compared to manual compression.
Conclusions: Arterial closure following coronary interventions using anticoagulation and GP IIb/IIIa inhibitor therapy can be safely and effectively performed, with vascular complication rates similar to or lower than with manual pressure. Additionally, vascular complication rates using GP IIb/IIIa inhibitor therapy regardless of the method of arterial closure are equivalent to or lower than previously published rates of vascular complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(02)01924-1 | DOI Listing |