Purpose: In this work, three-dimensional (3D) motion of lung tumors during radiotherapy in real time was investigated. Understanding the behavior of tumor motion in lung tissue to model tumor movement is necessary for accurate (gated or breath-hold) radiotherapy or CT scanning.

Methods: Twenty patients were included in this study. Before treatment, a 2-mm gold marker was implanted in or near the tumor. A real-time tumor tracking system using two fluoroscopy image processor units was installed in the treatment room. The 3D position of the implanted gold marker was determined by using real-time pattern recognition and a calibrated projection geometry. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within a certain volume. The system provided the coordinates of the gold marker during beam-on and beam-off time in all directions simultaneously, at a sample rate of 30 images per second. The recorded tumor motion was analyzed in terms of the amplitude and curvature of the tumor motion in three directions, the differences in breathing level during treatment, hysteresis (the difference between the inhalation and exhalation trajectory of the tumor), and the amplitude of tumor motion induced by cardiac motion.

Results: The average amplitude of the tumor motion was greatest (12 +/- 2 mm [SD]) in the cranial-caudal direction for tumors situated in the lower lobes and not attached to rigid structures such as the chest wall or vertebrae. For the lateral and anterior-posterior directions, tumor motion was small both for upper- and lower-lobe tumors (2 +/- 1 mm). The time-averaged tumor position was closer to the exhale position, because the tumor spent more time in the exhalation than in the inhalation phase. The tumor motion was modeled as a sinusoidal movement with varying asymmetry. The tumor position in the exhale phase was more stable than the tumor position in the inhale phase during individual treatment fields. However, in many patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement.The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments.

Conclusion: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0360-3016(02)02803-1DOI Listing

Publication Analysis

Top Keywords

tumor motion
52
tumor
28
tumor position
20
motion
16
gold marker
16
motion lung
12
real-time tumor
12
trajectory tumor
12
amplitude tumor
12
tumor tracking
8

Similar Publications

Background: Conventional treatments for knee osteoarthritis (KOA) often fall short in providing optimal outcomes.

Objective: To evaluate the effect of warm needle therapy guided by ultrasound on pain relief and physical function in patients with KOA.

Methods: In this retrospective study, the clinical records of patients with KOA undergoing either meloxicam alone or meloxicam combined with warm needle therapy were reviewed.

View Article and Find Full Text PDF

Postprandial glycaemic response and pain sensitivity in breast cancer survivors suffering from chronic pain: a double-blind, randomised controlled cross-over pilot experiment.

Support Care Cancer

January 2025

Pain in Motion Research Group (PAIN), Department of Physiotherapy, Human Physiology and Anatomy, Faculty of Physical Education and Physiotherapy, Vrije Universiteit Brussel, Laarbeeklaan 103 - 1090, Brussels, Belgium.

Introduction: The study's primary goal is to investigate differences in postprandial glycaemic response (PPGR) to beverages with varying glycaemic index (i.e. low and medium) between breast cancer survivors (BCS) with chronic pain and healthy pain-free controls (HC).

View Article and Find Full Text PDF

Synovial osteochondromatosis is a relatively rare condition of the hand. We present a rare case of a locked finger in a paediatric patient with synovial osteochondromatosis, in which a tumourous lesion was continuous with the flexor tendon and trapped proximal to the A1 pulley. After resection of the tumour and synovium, no recurrence was observed over a 6-month follow-up period.

View Article and Find Full Text PDF

Background: Exercise can attenuate the deleterious combined effects of cancer treatment and aging among older adults with cancer, yet exercise participation is low. Telehealth exercise may improve exercise engagement by decreasing time and transportation barriers; however, the utility of telehealth exercise among older adults with cancer is not well established.

Objective: We aimed to evaluate the preliminary effectiveness of a one-on-one, supervised telehealth exercise program on physical function, muscular endurance, balance, and flexibility among older adults with cancer.

View Article and Find Full Text PDF

A real-time tumor position prediction based multi-dimensional respiratory motion compensation puncture method.

Phys Med Biol

January 2025

Tianjin University, Centre for advanced Mechanisms and Robotics, Tianjin University, 135 Yaguan Road, Jinnan District, Tianjin, China., Tianjin, 300072, CHINA.

This study proposes a real-time tumor position prediction-based multi-dimensional respiratory motion compensation puncture method to accurately track real-time lung tumors and achieve precise needle puncture. Approach: A hybrid model framework integrating prediction and correlation models is developed to enable real-time tumor localization. A Long Short-Term Memory neural network with bidirectional and attention modules (Bi-LSTM-ATT) is employed for predicting external respiratory signals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!