Electroventilation with monopolar and bipolar intratracheal electrodes.

Anesth Analg

Department of Biomedical Engineering, Purdue University, 1293 A.A. Potter Building, West Lafayette, IN 47907, USA.

Published: July 2002

Unlabelled: Electroventilation is the technique of producing inspiration with stimuli applied to inspiratory muscles by using strategically placed electrodes on or within the body. We conducted studies using the dog to determine the efficacy of monopolar and bipolar intratracheal electrodes for electroventilation. Bipolar electrodes were able to produce an inspired volume greater than a spontaneous tidal volume in all seven dogs, but monopolar electrodes were able to in only three of seven dogs. The intratracheal electrode has the advantage over body-surface electrodes that less current is required to produce a single tidal volume, and it has the advantage over intraesophageal electrodes that anatomical placement of the electrode is simplified. These experiments demonstrated that a bipolar electrode can be used for electroventilation.

Implications: This study demonstrates that electroventilation is possible with intratracheal electrodes, decreasing the current needed to electroventilate by using body-surface electrodes. Two different methods of intratracheal electroventilation can be used: monopolar, in which the return electrode is on the body surface; and bipolar, in which the return electrode is in the trachea.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000539-200207000-00033DOI Listing

Publication Analysis

Top Keywords

intratracheal electrodes
12
electrodes
9
electroventilation monopolar
8
monopolar bipolar
8
bipolar intratracheal
8
tidal volume
8
body-surface electrodes
8
return electrode
8
electroventilation
5
bipolar
5

Similar Publications

During thyroidectomy, both needle electrodes (NE) and endotracheal tube electrodes (ETE) can be used. Incomplete contact of the endotracheal tube electrode with the vocal cords, endotracheal tube electrode may hinder an optimal outcome and even result in an inability to obtain an electromyography wave while neuromonitoring the external branch of the superior laryngeal nerve (EBSLN). There is no study that compares NE and ETE for EBSLN monitoring.

View Article and Find Full Text PDF

Bronchoscopy is a widely used technique for diagnostic and therapeutic purposes. Though it requires anesthesia, many options are available, depending on the patient's health status, the purpose of the procedure, and the type of bronchoscope used. One such health status is heart failure, a leading cause of death, and a common challenge of anesthesiology.

View Article and Find Full Text PDF
Article Synopsis
  • Accurate diagnosis and management of sudden ventilatory failure in children, especially during surgery, is essential.
  • A newborn undergoing pacemaker implantation experienced tracheal obstruction caused by vernix caseosa, which was only discovered after suctioning the tracheal tube.
  • Anesthesiologists should be aware that thick vernix caseosa can obstruct the airway right after suctioning in newborns.
View Article and Find Full Text PDF

Is trans-thyroid cartilage monitoring as good as endotracheal tube monitoring during thyroidectomy?

Eur Arch Otorhinolaryngol

October 2024

Department of Otolaryngology, Head and Neck Surgery, Meir Medical Center, 59 Tchernichovsky St, Kfar Saba, 4428164, Israel.

Article Synopsis
  • The study aimed to see if a new way of monitoring nerves during thyroid surgeries was just as good and safe as the usual method using an endotracheal tube.
  • They looked at 51 surgeries and found that the new method showed higher signals for certain nerves and no problems occurred when using it.
  • Overall, both methods worked similarly well, and the new monitoring technique could be a safe option for doctors during these operations.
View Article and Find Full Text PDF

Noninvasive monitoring of the vagus nerve during thyroid surgery using cutaneous adhesive and needle electrodes: What is the optimal configuration?

Head Neck

August 2024

Division of Thyroid and Parathyroid Endocrine Surgery, Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, Massachusetts, USA.

Objective: Endotracheal tube (ETT) surface electrodes are used to monitor the vagus nerve (VN), recurrent laryngeal nerve (RLN), and external branch of the superior laryngeal nerve (EBSLN) during thyroid and parathyroid surgery. Alternative nerve monitoring methods are desirable when intubation under general anesthesia is not desirable or possible. In this pilot study, we compared the performance of standard ETT electrodes to four different noninvasive cutaneous recording electrode types (two adhesive electrodes and two needle electrodes) in three different orientations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!