Background: Electrical disconnection of the myocardial extensions into arrhythmogenic pulmonary veins (PVs) is recognized as a curative technique for paroxysmal atrial fibrillation (AF). However, the presence of electrical connections between the PVs, which may make achievement of PV disconnection difficult, has not been systematically evaluated.
Methods And Results: Forty-nine consecutive patients with drug-resistant AF underwent ostial radiofrequency (RF) catheter ablation of arrhythmogenic PVs with foci triggering AF. Pacing from inside the targeted PV was performed after each RF delivery to identify the left atrial exit site of the residual venoatrial conduction. Successful PV disconnection was defined as achieving elimination of the PV potentials during sinus rhythm or left atrial pacing, and the loss of left atrial conduction during intra-PV pacing. A total of 112 arrhythmogenic PVs were identified. PV disconnection was achieved with 10+/-6.1 minutes of RF delivery to the ostia of 101 targeted PVs. In 7 left superior (LS) PVs from 7 patients (14%), the earliest atrial activity was recorded from the left inferior (LI) PV ostium during intra-LSPV pacing after 11+/-4.7 minutes of RF delivery to the LSPV ostium. Disconnection of these LSPVs was achieved by LIPV disconnection. In the remaining 4 PVs from 4 patients, PV disconnection could not be achieved.
Conclusions: Fourteen percent of the patients had electrical connections between contiguous PVs. In these patients, ostial ablation of an untargeted PV was required for successful targeted PV disconnection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/01.cir.0000019585.91146.ab | DOI Listing |
Epilepsia
January 2025
Academic Center for Epileptology (ACE), Kempenhaeghe/Maastricht UMC+, Maastricht & Heeze, Maastricht, The Netherlands.
Objective: To investigate whether local lesions created by stereo-electroencephalography (SEEG)-guided radiofrequency thermocoagulation (RFTC) affect distant brain connectivity and excitability in patients with focal, drug-resistant epilepsy (DRE).
Methods: Ten patients with focal DRE underwent SEEG implantation and subsequently 1 Hz bipolar repetitive electrical stimulation (RES) for 30 s before and after RFTC. Root mean square (RMS) of cortico-cortical evoked potentials (CCEPs) was calculated for 15 ms to 300 ms post-stimulation with baseline correction.
J Vis Exp
January 2025
School of Acupuncture-Moxibustion and Tuina, Beijing University of Chinese Medicine;
Electroacupuncture (EA) is one of the most commonly used methods in acupuncture and has a good effect on pain, depression, sensory movement disorders, and other diseases. The effectiveness of EA is influenced by many factors, such as the accuracy of acupoint selection, the duration and course of EA treatment, and EA parameters. However, it has rarely been discussed whether the positive and negative electrodes of the EA instrument with acupoints at different locations and distances have an effect on the curative effect.
View Article and Find Full Text PDFElectrophoresis
January 2025
Department of Toxicology, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Kepala Batas, Pulau Pinang, Malaysia.
Advancements in food technology have increased the need for thorough analysis to ensure food safety, quality, and compliance with regulatory requirements. Capillary electrophoresis-mass spectrometry (CE-MS) has emerged as a powerful tool in food analysis due to its high separation efficiency, low sample consumption, and ability to handle complex matrices. However, challenges such as the use of volatile running buffers and maintaining the stability of the electrical circuit connecting the CE and MS systems have been addressed through advancements in interface designs, such as sheathless systems and optimized sheath-liquid compositions.
View Article and Find Full Text PDFACS Photonics
January 2025
Electrical and Computer Engineering Department, University of California, Santa Barbara, California 93106, United States.
Correlated photon-pair sources are key components for quantum computing, networking, synchronization, and sensing applications. Integrated photonics has enabled chip-scale sources using nonlinear processes, producing high-rate time-energy and polarization entanglement at telecom wavelengths with sub-100 microwatt pump power. Many quantum systems operate in the visible or near-infrared ranges, necessitating visible-telecom entangled-pair sources for connecting remote systems via entanglement swapping and teleportation.
View Article and Find Full Text PDFFront Neurol
January 2025
Oregon Hearing Research Center, Oregon Health & Science University, Portland, OR, United States.
Introduction: The brainstem vestibular nuclei neurons receive synaptic inputs from inner ear acceleration-sensing hair cells, cerebellar output neurons, and ascending signals from spinal proprioceptive-related neurons. The lateral (LVST) and medial (MVST) vestibulospinal (VS) tracts convey their coded signals to the spinal circuits to rapidly counter externally imposed perturbations to facilitate stability and provide a framework for self-generated head movements.
Methods: The present study describes the morphological characteristics of intraaxonally recorded and labeled VS neurons monosynaptically connected to the 8th nerve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!