Digital camera technology has developed rapidly and a large choice of reasonably priced, user-oriented models are now available. These can be used for both macroscopic and microscopic photography with good resolution. Internet transmission of digital images also makes it possible to consult pathologists anywhere in the world. This study tests a simple, fast, and inexpensive method for practical transmission of images for diagnosis using a digital camera and the Internet. Using a commercial digital camera mounted with a phototube adapter to a light microscope (6 images per case on average), 2210 digital images (310 Mb) from 347 cases of gastrointestinal, lung, and uterus specimens were captured. Each image, stored in medium compression JPEG (Joint Photographers Experts Group) format with 1024 x 768 pixel resolution, required approximately 5 seconds to capture after the case had been reviewed and appropriate fields for imaging selected (30 seconds per case on average). The images were transmitted from Samsung Medical Center, Seoul, to Korea University Hospital, Seoul, and John Hunter Hospital, Newcastle, Australia. Transmission was 100% successful with a total upload time of 3 hours for 310 MB of data (31 seconds per case on average). The images were downloaded in 2 hours and viewed on a 17-inch color monitor with a maximal resolution of 1280 x 1024 pixels. Telepathology diagnoses were made with 95% and 97% concurrence by two pathologists at Korea University Hospital and John Hunter Hospital, respectively. We suggest that the current level of commercial technology yields fast, convenient and economical tools for practical telepathology diagnosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/15305620260008093 | DOI Listing |
ANZ J Surg
December 2024
Royal Prince Alfred Institute of Academic Surgery, Sydney Local Health District, Sydney, New South Wales, Australia.
Background: Facial prosthetics are an important means to rehabilitate patients with congenital or acquired facial defects. However, with a time-consuming manual workflow and workforce shortage, access to facial prosthetics is limited in Australia and worldwide, especially for rural and remote patients. Optical 3D scanning has been increasingly integrated in digitizing data.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Physics, Lakehead University, Thunder Bay, Ontario, Canada.
Background: This study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer.
View Article and Find Full Text PDFVet Sci
December 2024
College of Agriculture & Environmental Sciences, University of South Africa, Private Bag X6, Roodepoort 1710, South Africa.
Ticks are a significant threat to livestock globally, with certain species displaying distinct host preferences at various developmental stages. Accurate species-level identification is essential for studying tick populations, implementing control strategies, and understanding disease dynamics. This study evaluated ticks infesting cattle across six provinces in South Africa using morphological and molecular methods.
View Article and Find Full Text PDFBiomimetics (Basel)
November 2024
Ocean and Maritime Digital Technology Research Division, Korea Research Institute of Ships and Ocean Engineering, Daejeon 34103, Republic of Korea.
Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber.
View Article and Find Full Text PDFJ Esthet Restor Dent
December 2024
Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkiye.
Objective: This study aimed to compare dental plaque scores measured using clinical examination and different imaging methods.
Materials And Methods: Twenty-eight volunteers were included in the study and divided into two groups according to DMFT (D: Decayed, M: Missing, F: Filling, T: Teeth) scores (under 3 and over 10). Dental plaque on anterior labial surfaces' was scored using clinical visual examination with/without staining and different imaging systems (Digital photography, intraoral digital scanning, FluoreCam).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!