Eight patients with acoustic neuromas were treated using a novel method developed at our institution for delivering fractionated stereotactic intensity-modulated radiotherapy (FS-IMRT). We present treatment parameters, dosimetry analysis, and preliminary clinical outcome. The method incorporates high-precision invasive fixation, obliquely-oriented tomotherapy arcs, and reduced dimension pencil beams. The delivered dose distributions for the 8 patients treated from April 1999 to May 2001 were assessed for dose conformality, homogeneity, and doses to organs at risk. Total doses prescribed were 54 Gy in daily doses of 1.8 Gy. Results show that the median planning target volume (gross tumor volume plus a safety margin of 2 mm) was 2.48 cm3 (1.64 to 16.86 cm3) and that the median conformality and homogeneity indices were 1.69 (1.56 to 2.16) and 1.12 (1.09 to 1.19), respectively. The respective average mean and maximum doses to the brain stem were 12.67 Gy and 53.86 Gy. The treatment parameters for the novel FS-IMRT method developed here document excellent dose conformality and normal tissue sparing. Preliminary short-term follow-up (mean 17, median 18.5 months) revealed a 100% local control and hearing preservation rate. No new persistent impairment of facial and trigeminal nerve was observed. Our current follow-up experience indicates a reasonable potential for achieving outcomes comparable to established stereotactic radiotherapy techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0958-3947(02)00097-3DOI Listing

Publication Analysis

Top Keywords

fractionated stereotactic
8
stereotactic intensity-modulated
8
intensity-modulated radiotherapy
8
radiotherapy fs-imrt
8
acoustic neuromas
8
method developed
8
treatment parameters
8
dose conformality
8
conformality homogeneity
8
fs-imrt small
4

Similar Publications

Aim: To evaluate the efficacy of 25Gy/5# prophylactic pelvic nodal irradiation for regional control during stereotactic radiotherapy (SBRT) for high risk prostate cancer.

Methods: The multinational XXXX consortium database of patients treated with curative-intent prostate SBRT for high risk prostate cancer was queried for prophylactic radiotherapy 25Gy/5# to the pelvic lymph nodes. Details of Phoenix-defined biochemical failure, and location of recurrence (local, regional, or distant) were extracted.

View Article and Find Full Text PDF

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

Background And Purpose: The aim was to estimate the cost of the external beam radiotherapy (EBRT) in public health care centers in Catalonia (Spain), according to the ESTRO-HERO costing model for 2018.

Materials And Methods: Personnel, equipment, and activity data from 2018 from the 11 RT centers were used, incorporating European mean values adapted to the Catalan context. Secondly, EBRT costs were estimated, incorporating 2023 fractionation technique and scheme usage percentages.

View Article and Find Full Text PDF

Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia.

Radiat Oncol J

December 2024

Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.

Purpose: Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.

View Article and Find Full Text PDF

Intrafraction Patient Positional Uncertainty in Lung Stereotactic Ablative Radiotherapy with Abdominal Compression.

Pract Radiat Oncol

December 2024

Department of Radiation Oncology, Willis Knighton Cancer Center, 2600 Kings Highway, Shreveport, Louisiana, USA 71103 &, Department of Clinical Research, University of Jamestown, Fargo, ND, USA. Electronic address:

Purpose: Motion management presents a significant challenge in thoracic stereotactic ablative radiotherapy (SABR). Currently, a 5.0 mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!