Objective: To assess the accuracy of echocardiography for hemodynamic monitoring.
Data Sources: A computerized MEDLINE search was used with the following search headings: monitoring (physiologic and intra-operative) and both echocardiography and transesophageal echocardiography. A number of studies were obtained from the reference lists of cardiology reviews and textbooks.
Study Selection: Studies that were designed to assess the accuracy of hemodynamic monitoring.
Data Extraction: From the selected studies, the accuracy of different techniques for measuring preload and cardiac output was compared.
Data Synthesis: Hypovolemia can be detected accurately by measuring left ventricular end-diastolic area. At high preload, Doppler-based methods are more accurate, although further studies in critical care patients are needed. Cardiac output is best measured by measuring Doppler flow, preferably across the aortic valve.
Conclusions: Echocardiography can be used to make accurate hemodynamic measurements; however, training is required. Further studies are needed to validate these methods in the management of critically ill patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00003246-200206000-00039 | DOI Listing |
J Clin Med
December 2024
Cardiovascular Pathophysiology and Genomics Research Unit, School of Physiology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg 2193, South Africa.
The study aimed to assess the potential impacts of mean arterial pressure (MAP) and its determinants (cardiac output and systemic vascular resistance) on diabetic nephropathy (DNP)-associated impaired aortic function. This multi-ethnic study included 115 chronic kidney disease (CKD) patients (67 non-dialysis and 48 dialysis). Six aortic function measures were evaluated by SpygmoCor.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiac Surgery, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo 105-8461, Japan.
Aortic valvuloplasty for bicuspid aortic valve carries a risk of postoperative stenosis. We evaluated the haemodynamic differences between aortic valvuloplasty for bicuspid aortic valve, tricuspid aortic valve, and aortic valve replacement by echocardiography. We also assessed whether a higher postoperative pressure gradient affects the outcomes of aortic valvuloplasty for bicuspid aortic valve.
View Article and Find Full Text PDFBiomolecules
December 2024
Department of Internal Medicine II, Division of Cardiology, Paracelsus Medical University, 5020 Salzburg, Austria.
Background: Despite existing evidence of the high predictive value of natriuretic peptides (NPs) in patients with heart failure (HF), patients treated with guideline-directed therapy who have low or near-normal NP levels are unlikely to be correctly stratified for risk of clinical outcomes. The aim of this study is to detect plausible predictors for poor one-year clinical outcomes in patients with HFpEF and low NT-proBNP treated with in accordance with conventional guidelines.
Methods: A total of 337 patients with HF with preserved ejection fraction (HFpEF) who had low levels of N-terminal natriuretic pro-peptide (NT-proBNP) at discharge due to optimal guideline-based therapy were enrolled in the study.
Animals (Basel)
December 2024
Department of Animal Medicine and Surgery, University of Cordoba, 14014 Cordoba, Spain.
Systemic inflammatory response syndrome (SIRS) in donkeys is observed to be secondary to colic, diarrhea or pleuropneumonia, among other disorders. Horses with SIRS develop secondary disturbances such as hyperlipemia, laminitis, disseminated intravascular coagulopathy, and hemodynamic and cardiac derangements, which impair their prognosis and increase the mortality rate. In donkeys, no information is available on the effect of experimentally induced endotoxemia in the cardiovascular system.
View Article and Find Full Text PDFEchocardiography
January 2025
Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
Objective: Diastolic dysfunction (DD) is defined as impaired left ventricular (LV) relaxation, caused by structural or functional heart diseases. We sought to assess the role of cardiac CT angiography (CCTA) as a tool to evaluate LV DD in patients with normal EF using the diastolic expansion index (DEI), as compared to transthoracic echocardiography (TTE) as the gold standard.
Methods: Patients presenting with atypical chest pain with suspected coronary artery disease (CAD) and having a normal LV ejection fraction on TTE underwent CCTA using a dual source CT scanner.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!