Exercise-induced oxyhaemoglobin desaturation, ventilatory limitation and lung diffusing capacity in women during and after exercise.

Eur J Appl Physiol

Discipline of Anatomy and Physiology, School of Medicine, University of Tasmania, GPO Box 252-24, Hobart 7001, Australia.

Published: June 2002

Arterial haemoglobin saturation during exercise in healthy young women [eight subjects mean (SEM) age 20.8 (1.8) years] was measured to confirm the theory that young women experience exercise-induced arterial hypoxaemia (EIAH) at a lower relative percentage of maximal oxygen uptake (VO(2max)) than has been documented in their male counterparts. To determine if flow limitation [the percentage of the tidal volume ( V(T)) that met or exceeded the boundary established by multiple maximal expiratory manoeuvres] and/or post-exercise lung diffusing capacity are linked to EIAH in women, and to investigate the influence of exercise intensity and duration on post-exercise carbon monoxide lung diffusing capacity ( D(L, CO)), these parameters were measured during and after three exercise tests (incremental test until exhaustion, 5 km run and 5 km run with sprint). All subjects experienced physiologically significant EIAH (a fall of more than 3% in oxygen saturation of arterial blood from levels at rest) and seven subjects experienced flow limitation during the VO(2max) protocol [mean (SD) 12.2 (8.8)% of V(T)]. Even though there was no significant relationship between aerobic capacity and the degree of flow limitation ( r=0.33, P>0.05), the flow limitation was related to absolute ventilation in the subjects studied ( r=0.82, P<0.05). There was no significant relationship between decrements in post exercise D(L, CO) and EIAH ( r=0.05, P>0.05), however there was a strong correlation between the extent of flow limitation (% of V(T)) and EIAH ( r=0.71). Significant decreases in D(L, CO) lasted for up to 16 h after each of the exercise tests ( P<0.05) and lasted for a further 8 h after the maximal test ( P<0.05). Exercise intensity was the main contributing factor to the observed decreases in post-exercise D(L, CO) with the percentage of VO(2max) attained during the various tests being significantly related to the fall in D(L, CO) for 1, 2, 3, 16 and 24 h after exercise ( P<0.05). As the appearance of flow limitation closely coincided with the appearance of EIAH, the results from the present study suggest that flow limitation is a contributing factor to EIAH in women although the exact mechanism remains unclear.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00421-002-0600-xDOI Listing

Publication Analysis

Top Keywords

flow limitation
20
lung diffusing
12
diffusing capacity
12
young women
8
exercise tests
8
subjects experienced
8
limitation
6
exercise
5
flow
5
exercise-induced oxyhaemoglobin
4

Similar Publications

Tick-borne spotted fever rickettsioses (SFRs) continue to cause severe illness and death in otherwise-healthy individuals due to lack of a timely and reliable diagnostic laboratory test. We recently identified a diagnostic biomarker for SFRs, the putative N-acetylmuramoyl-l-alanine amidase RC0497. Here, we developed a prototype laboratory test that targets RC0497 for diagnosis of SFRs.

View Article and Find Full Text PDF

While soundscapes shape the structure and function of auditory systems over evolutionary timescales, there is limited information regarding the adaptation of wild fish populations to their natural acoustic environments. This is particularly relevant for freshwater ecosystems, which are extremely diverse and face escalating pressures from human activities and associated noise pollution. The Siamese fighting fish is one of the most important cultured species in the global ornamental fish market and is increasingly recognized as a model organism for genetics and behavioural studies.

View Article and Find Full Text PDF

Balancing pH and Pressure Allows Boosting Voltage and Power Density for a H-I Redox Flow Battery.

ACS Appl Energy Mater

January 2025

Department of Chemical Engineering, Delft University of Technology, Van der Maasweg 9, 2629HZ Delft, The Netherlands.

The decoupled power and energy output of a redox flow battery (RFB) offers a key advantage in long-duration energy storage, crucial for a successful energy transition. Iodide/iodine and hydrogen/water, owing to their fast reaction kinetics, benign nature, and high solubility, provide promising battery chemistry. However, H-I RFBs suffer from low open circuit potentials, iodine crossover, and their multiphase nature.

View Article and Find Full Text PDF

The twin reversed arterial perfusion (TRAP) sequence is a rare complication associated with monochorionic twins. It is characterized by blood flow from the umbilical artery of the normal (pump) twin to the umbilical artery of the abnormal (acardiac) twin via artery-to-artery anastomosis. This condition is associated with 100% mortality in the acardiac twin and a high rate of perinatal morbidity and mortality in the pump twin, primarily due to intrauterine hypoxic injury, heart failure, and prematurity.

View Article and Find Full Text PDF

Anomalous aortic origin of coronary artery can lead to ischemia. Due to the limitations of invasive catheterization dobutamine stress testing, an alternative noninvasive approach is desired. A 65-year-old woman with atypical chest pain was referred for coronary computed tomography angiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!