Objective: To evaluate the safety and efficacy of heparin-coated perfusion circuits with low-dose heparinization and centrifugal pumping compared with the standard method during coronary artery bypass grafting.
Design: Prospective, randomized, single-blind clinical trial.
Setting: A primary care institution.
Patients: Ninety patients who underwent first-time elective coronary artery bypass grafting were eligible for the study. After giving informed consent, they were randomly assigned to 1 of 3 groups (30/group).
Interventions: Perfusion on regular uncoated bypass equipment with a roller pump and full-dose heparinization (300 IU/kg bolus, activated clotting time [ACT] > 400 s) (group 1), on a heparin-coated oxygenator with a centrifugal pump and full-dose heparinization (group 2) and on fully heparin-coated bypass equipment with a centrifugal pump and low-dose heparinization (100 IU/kg bolus, ACT of 180-400 s) (group 3). Standard coronary artery bypass grafting was performed.
Outcome Measures: Postoperative bleeding, transfusion requirements and clinical outcomes.
Results: There were no complications related to the study protocol. Study groups were similar in terms of postoperative bleeding, transfusion requirements and clinical outcomes.
Conclusions: Heparin-coated cardiopulmonary bypass with low-dose heparinization and centrifugal pumping is a safe practice but showed no advantages over the use of regular uncoated bypass circuits for coronary bypass surgery.