AI Article Synopsis

  • Ultrasound was used on 32 ewes with various litter sizes to estimate pregnancy stages between 60 to 120 days of gestation, achieving high measurement success rates.
  • The study found that the accuracy of pregnancy stage predictions using fetal bone measurements (metacarpal bone length and biparietal diameter) was reliable, with mean absolute errors around 2.2 to 3.3 days depending on the method used.
  • Including average measurements from multiple fetuses within a litter and employing multiple regression analyses improved the predictive capacity of ultrasound for estimating pregnancy stages.

Article Abstract

The use of ultrasound to estimate stage of pregnancy was assessed in 32 ewes of a prolific genotype carrying 7 singleton fetuses and 9 twin, 10 triplet and 6 quadruplet litters that were scanned on six occasions from 60 to 120 days of gestation. At least one ultrasound measurement per ewe of fetal metacarpal bone length (MCL), biparietal diameter (BPD), or of both bones was made on over 90% of attempts (n = 152). Measurement of MCL was made on 78% of attempts (n = 371), of BPD on 73% of attempts, and of both bones on 62% of attempts. The equation developed from BPD (mean absolute error (MAE) = 3.2 days) was similar to that developed from measurement of MCL (MAE = 3.3 days) in its capacity to predict stage of pregnancy. Accuracy of prediction was improved using equations that included mean values within litters for BPD (MAE = 2.5 days) and MCL (MAE = 2.6 days). Further improvement in predictive capacity was achieved using multiple regression equations developed from measurement of both bones (individual fetuses: MAE = 2.6 days; equations including mean values within litters: MAE = 2.2 days). The results demonstrate that ultrasound can be used to estimate stage of pregnancy in prolific ewes, and that the use of mean values for bone measurements from different fetuses within litters and/or measurement of bones with different growth allometry can increase the reliability of estimates. The utility of the procedure depends on the number of fetuses measured per ewe, the number of bones measured per fetus and, hence, the time required to measure bones and the degree of accuracy required.

Download full-text PDF

Source
http://dx.doi.org/10.1071/rd01047DOI Listing

Publication Analysis

Top Keywords

mae days
24
stage pregnancy
16
pregnancy prolific
8
ultrasound measurement
8
ultrasound estimate
8
estimate stage
8
measurement mcl
8
developed measurement
8
mcl mae
8
values litters
8

Similar Publications

Heat extremes become increasingly frequent and severe, posing adverse risks to public health and environment. Previous research on extreme heat mostly used meteorological observations or reanalysis data, which cannot well capture detailed spatial patterns. This study developed a seamless air temperature (T) dataset from remote sensing data to characterize the spatio-temporal variations of heat extremes in the Yangtze River Delta (YRD) from 2001 to 2023.

View Article and Find Full Text PDF

Aims: To explore all medication administration errors (MAEs) throughout the entire process of medication administration by nurses in the inpatient setting, to describe their prevalence, and to analyse associated factors, including deviation from the good practice standards.

Background: Worldwide, MAEs are very common and regarded as a serious risk factor to inpatient safety. Nurses assume an essential role in the hospital setting during the administration of medications.

View Article and Find Full Text PDF

Accurate calibration of finite element (FE) models is essential across various biomechanical applications, including human intervertebral discs (IVDs), to ensure their reliability and use in diagnosing and planning treatments. However, traditional calibration methods are computationally intensive, requiring iterative, derivative-free optimization algorithms that often take days to converge. This study addresses these challenges by introducing a novel, efficient, and effective calibration method demonstrated on a human L4-L5 IVD FE model as a case study using a neural network (NN) surrogate.

View Article and Find Full Text PDF

Background/objectives: Renal anemia is one of the major complications associated with chronic kidney disease (CKD). Erythropoietin-stimulating agents (ESAs) are commonly used; however, some patients exhibit resistance. Hypoxia-inducible factor prolyl-hydroxylase inhibitors (HIF-PHIs) have emerged as a novel treatment for renal anemia, enhancing erythropoiesis and iron metabolism.

View Article and Find Full Text PDF

Background: Posterior lumbar fusion (PLF) is a common spine surgery that may be considered in patients with underlying comorbidities, such as inflammatory bowel disease (IBD). Prior literature examining the association of this disease and PLF outcomes was done in the National Inpatient Sample (NIS), which only assessed in-hospital data and did not reveal an elevated risk of medical or surgical complications. However, characterization of PLF outcomes beyond hospital discharge is important and remains unknown for patients with IBD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!