A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion. | LitMetric

In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion.

Physiol Meas

Nuclear Engineering Research Laboratory, University of Tokyo, Tokai-mura, Ibaraki, Japan.

Published: May 2002

As endothelial cells are subject to flow shear stress, it is important to determine the detailed velocity distribution in microvessels in the study of mechanical interactions between blood and endothelium. Recently, particle image velocimetry (PIV) has been proposed as a quantitative method of measuring velocity fields instantaneously in experimental fluid mechanics. The authors have developed a highly accurate PIV technique with improved dynamic range. spatial resolution and measurement accuracy. In this paper, the proposed method was applied to images of the arteriole in the rat mesentery using an intravital microscope and high-speed digital video system. Taking the mesentery motion into account, the PIV technique was improved to measure red blood cell (RBC) velocity. Velocity distributions with spatial resolutions of 0.8 x 0.8 microm were obtained even near the wall in the centre plane of the arteriole. The arteriole velocity profile was blunt in the centre region of the vessel cross-section and sharp in the near-wall region. Typical flow features for non-Newtonian fluid were shown. Time-averaged velocity profiles in six cross sections with different diameters were compared.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/23/2/315DOI Listing

Publication Analysis

Top Keywords

red blood
8
blood cell
8
mesentery motion
8
piv technique
8
technique improved
8
velocity
7
vivo piv
4
piv measurement
4
measurement red
4
cell velocity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!