Purpose: Gynecare tension-free vaginal tape (Ethicon, Inc., New Brunswick, New Jersey) is a propylene mesh tape recently introduced in the United States as minimally invasive treatment for stress urinary incontinence. We report the combined experience at 3 tertiary care institutions with graft erosion and bladder outlet obstruction after procedures performed elsewhere.

Materials And Methods: We reviewed the records of 5 patients with complications who presented to 1 of 3 institutions after polypropylene mesh tape placement. All pertinent information was obtained from the medical records and the operating surgeon at the referring institution.

Results: Treatment was required in 2 patients with urethral erosion, 1 with vaginal and bladder erosion, and 2 with bladder outlet obstruction. Common presenting symptoms included urge, urge incontinence and gross hematuria. Cystoscopy showed polypropylene graft erosion at the urethra or through the bladder wall. Each patient required explantation of the polypropylene mesh tape and further surgery to restore continence. The graft was divided transvaginally in the 2 patients presenting with outlet obstruction. Urge incontinence resolved and they returned to complete spontaneous voiding.

Conclusions: High clinical suspicion is necessary when evaluating patients presenting with urinary symptoms after polypropylene mesh tape placement. Bladder outlet obstruction and possible graft erosion should be considered.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mesh tape
20
outlet obstruction
20
polypropylene mesh
16
graft erosion
12
bladder outlet
12
stress urinary
8
urinary incontinence
8
urethral erosion
8
erosion bladder
8
tape placement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!