Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz.

Phys Med Biol

Department of Electrical and Computer Engineering, University of Utah, Salt Lake City 84112, USA.

Published: May 2002

This paper compares the maximum allowable powers of some typical cellular telephones at 835 and 1900 MHz for compliance with the limits of specific absorption rates (SAR) given in ANSI/IEEE, ICNIRP and the proposed modification of ANSI/IEEE safety guidelines. It is shown that the present ANSI/IEEE guideline is the most conservative with the ICNIRP guidelines allowing a maximum radiated powerthat is 2.5-3 times higher, and the proposed IEEE modification of treating pinna as an extremity tissue the least conservative allowing even higher radiated powers by up to 50%. The paper also expands the previously reported study of energy deposition in models of adults versus children to two different and distinct anatomically-based models of the adult head, namely the Utah model and the 'Visible Man' model, each of which is increased or reduced by the voxel size to obtain additional head models larger or smaller in all dimensions by 11.1% or -9.1%, respectively. The peak 1 g body-tissue SAR calculated using the widely accepted FDTD method for smaller models is up to 56% higher at 1900 MHz and up to 20% higher at 835 MHz compared to the larger models, with the average models giving intermediate SARs. Also given in the paper is a comparison of the peak 1 g and 10 g SARs for two different anatomically-based models with 6 mm thick smooth plastic ear models used for SAR compliance testing. The SARs obtained with the insulating plastic ear models are up to two or more times smaller than realistic anatomic models. We propose a 2 mm thin shell phantom with lossy ear that should give SARs within +/- 15% of those of anatomic models.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/47/9/306DOI Listing

Publication Analysis

Top Keywords

1900 mhz
12
models
11
sar compliance
8
compliance testing
8
cellular telephones
8
telephones 835
8
835 1900
8
anatomically-based models
8
plastic ear
8
ear models
8

Similar Publications

Background: Oxidative stress is thought to be related to many diseases. Furthermore, it is hypothesized that radiofrequency electromagnetic fields (RF-EMF) may induce excessive oxidative stress in various cell types and thereby have the potential to compromise human and animal health. The objective of this systematic review (SR) is to summarize and evaluate the literature on the relation between the exposure to RF-EMF in the frequency range from 100 kHz to 300 GHz and biomarkers of oxidative stress.

View Article and Find Full Text PDF

Spin-photon interaction in a nanowire quantum dot with asymmetrical confining potential.

J Phys Condens Matter

February 2024

Key Laboratory for Microstructural Material Physics of Hebei Province, School of Science, Yanshan University, Qinhuangdao 066004, People's Republic of China.

The electron (hole) spin-photon interaction is studied in an asymmetrical InSb (Ge) nanowire quantum dot. The spin-orbit coupling in the quantum dot mediates not only a transverse spin-photon interaction, but also a longitudinal spin-photon interaction due to the asymmetry of the confining potential. Both the transverse and the longitudinal spin-photon interactions have non-monotonic dependence on the spin-orbit coupling.

View Article and Find Full Text PDF

We report on the design and characterization of a compact microwave antenna for atomic and molecular physics experiments. The antenna is comprised of four loop antennas arranged in a cloverleaf shape, allowing for precise adjustment of polarization by tuning the relative phase of the loops. We optimize the antenna for left-circularly polarized microwaves at 3.

View Article and Find Full Text PDF

Assessment of the electromagnetic field exposure due to wireless communication technologies in two university campuses of medellin, Colombia.

Heliyon

September 2023

Advanced Materials and Energy Research Group, Faculty of Engineering, Instituto Tecnologico Metropolitano ITM, Medellin, Colombia.

Exposure to radiofrequency electromagnetic fields (RF-EMFs) is considered an area of significant importance in the medical and scientific community. However, the availability of exposure data for indoor and outdoor locations in universities is limited and currently inconsiderate in Latin America. The aim of this work was to evaluate the electric field levels due to mobile telecommunication technologies and Wi-Fi to which students and faculty staff from two campuses of a higher education institution are exposed.

View Article and Find Full Text PDF

We present an experimental investigation of supercontinuum generation in potassium gadolinium tungstate (KGW) and yttrium vanadate (YVO) crystals pumped with 210 fs, 1030 nm pulses from an amplified Yb:KGW laser operating at 2 MHz repetition rate. We demonstrate that compared to commonly used sapphire and YAG, these materials possess considerably lower supercontinuum generation thresholds, produce remarkable red-shifted spectral broadenings (up to 1700 nm in YVO and up to 1900 nm in KGW) and exhibit less bulk heating due to energy deposition during filamentation process. Moreover, durable damage-free performance was observed without any translation of the sample, suggesting that KGW and YVO are excellent nonlinear materials for high repetition rate supercontinuum generation in the near and short-wave infrared spectral range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!