An external device ("rottometer") specially designed to measure knee joint rotation was developed and evaluated with respect to its validity. Simultaneous measurements were made with the rottometer and Roentgen stereometric analysis (RSA) in five patients with implanted tantalum markers in the tibia and femur. Measurements of internal and external rotation were made at 90 degrees and 60 degrees of knee flexion using 3, 6 and 9 N m torques. The coefficients of determination (r2) between the results obtained with the rottometer and RSA were around 0.9 for the total rotation. The rottometer consistently overestimated the rotation by about 100% and this systematic error was most constant at 90 degrees flexion for the different torques. The magnitude of this error from soft tissue deformation as well as the rotatory movements in the hip, foot and ankle joints must be considered when using external devices to measure knee rotation in clinical studies. The most accurate registrations were found in 90 degrees flexion with 9 N m force (r2 = 0.94).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0736-0266(01)00148-6 | DOI Listing |
JMIR Med Inform
January 2025
School of Software, Taiyuan University of Technology, Jingzhong, China.
Background: The prompt and accurate identification of mild cognitive impairment (MCI) is crucial for preventing its progression into more severe neurodegenerative diseases. However, current diagnostic solutions, such as biomarkers and cognitive screening tests, prove costly, time-consuming, and invasive, hindering patient compliance and the accessibility of these tests. Therefore, exploring a more cost-effective, efficient, and noninvasive method to aid clinicians in detecting MCI is necessary.
View Article and Find Full Text PDFACS Photonics
January 2025
Department of Physics, University of Pittsburgh, 3941 O'Hara Street, Pittsburgh, Pennsylvania 15218, United States.
We report the canonical properties of the Bose-Einstein condensation of polaritons in the weak coupling regime, seen previously in many low-temperature experiments, at room temperature in a GaAs/AlGaAs structure. These effects include a nonlinear energy shift of the polaritons, showing that they are not noninteracting photons, and dramatic line narrowing due to coherence, giving coherent emission with a spectral width of 0.24 meV at room temperature with no external stabilization.
View Article and Find Full Text PDFACS Photonics
January 2025
Photonic Nanomaterials, Istituto Italiano di Tecnologia, 16163 Genova, Italy.
Colloidal semiconductor nanocrystals (NCs) are an efficient and cost-effective class of nanomaterials for optoelectronic applications. Advancements in NC-based optoelectronic devices have resulted from progress in synthetic chemistry, adjustable surface properties, and optimized device architectures. Semiconductor nanoplatelets (NPLs) stand out among other NCs due to their precise growth control, yielding uniform thickness with submonolayer roughness.
View Article and Find Full Text PDFFront Netw Physiol
January 2025
Institut für Theoretische Physik, Technische Universität Berlin, Berlin, Germany.
All cells in the human body, including cancer cells, possess specific electrical properties crucial for their functions. These properties are notably different between normal and cancerous cells. Cancer cells are characterized by autonomous oscillations and damped electromagnetic field (EMF) activation.
View Article and Find Full Text PDFBackground: Currently, a majority of institution-specific automatic MRI-based contouring algorithms are trained, tested, and validated on one contrast weighting (i.e., T2-weighted), however their actual performance within this contrast weighting (i.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!