A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Recording and marking with silicon multichannel electrodes. | LitMetric

Recording and marking with silicon multichannel electrodes.

Brain Res Brain Res Protoc

Department of Computer Science, Algoma University College, Sault Ste. Marie, Ontario, Canada.

Published: April 2002

This protocol describes an implementation of recording and analysis of evoked potentials in the hippocampal cortex, combined with lesioning using multichannel silicon probes. Multichannel recording offers the advantage of capturing a potential field at one instant in time. The potentials are then subjected to current source density (CSD) analysis, to reveal the layer-by-layer current sources and sinks. Signals from each channel of a silicon probe (maximum 16 channels in this study) were amplified and digitized at up to 40 kHz after sample-and-hold circuits. A modular lesion circuit board could be inserted between the input preamplifiers and the silicon probe, such that any one of the 16 electrodes could be connected to a DC lesion current. By making a lesion at the electrode showing a physiological event of interest, the anatomical location of the event can be precisely identified, as shown for the distal dendritic current sink in CA1 following medial perforant path stimulation. Making two discrete lesions through the silicon probe is useful to indicate the degree of tissue shrinkage during histological procedures. In addition, potential/CSD profiles were stable following small movements of the silicon probe, suggesting that the probe did not cause excessive damage to the brain.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1385-299x(02)00139-3DOI Listing

Publication Analysis

Top Keywords

silicon probe
16
silicon
6
probe
5
recording marking
4
marking silicon
4
silicon multichannel
4
multichannel electrodes
4
electrodes protocol
4
protocol describes
4
describes implementation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!