A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. | LitMetric

Objective: To compare a custom-made femoral stem with a conventional cementless stem for initial stability in human femurs.

Design: The bone-femoral prosthesis interface motion was measured in vitro using displacement transducers. Combined axial and torsional loads simulating single-leg stance, loading were applied.

Background: The custom-made prosthesis is a cementless femoral stem fabricated from the patient's CT-reconstruction. To justify its clinical use its design has to be tested regarding his primary stability.

Methods: Seven pairs of human cadaveric femurs were used for testing the custom-made prosthesis versus a conventional cementless stem. Subsidence, rotation and interface motion were measured with load cycles up to 2000 N.

Results: The critical interface motion of 150 microm for the cementless prosthesis was not exceed for both types of prosthesis. The custom-made prosthesis enlarged in its metaphyseal part showed a decrease of dynamic micromotions and rotation behavior in the proximal region compared to the Alloclassic prosthesis stem.

Conclusions: The initial stability of the custom-made femoral stem was comparable to that of a conventional femoral stem.

Relevance: The data set for initial stability justifies the clinical use of a custom-made femoral stem in primary hip replacement. An individualized stem fit into the endosteal cortical bone decrease micromotion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0268-0033(02)00012-8DOI Listing

Publication Analysis

Top Keywords

femoral stem
16
custom-made femoral
12
initial stability
12
interface motion
12
custom-made prosthesis
12
cementless femoral
8
versus conventional
8
conventional femoral
8
prosthesis
8
conventional cementless
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!