Electropolymerization of aniline in the presence of poly(acrylic acid) on Au electrodes yields a polyaniline/poly(acrylic acid) composite film, exhibiting reversible redox functions in aqueous solutions at pH = 7.0. In situ electrochemical-SPR measurements are used to identify the dynamics of swelling and shrinking of the polymer film upon the oxidation of the polyaniline (PAn) to its oxidized state (PAn(2+)) and the reduction of the oxidized polymer (PAn(2+)) back to its reduced state (PAn), respectively. Covalent attachment of N(6)-(2-aminoethyl)-flavin adenin dinucleotide (amino-FAD, 1) to the carboxylic groups of the composite polyaniline/poly(acrylic acid) film followed by the reconstitution of apoglucose oxidase on the functional polymer yields an electrically contacted glucose oxidase of unprecedented electrical communication efficiency with the electrode: electron-transfer turnover rate approximately 1000 s(-1) at 30 degrees C. In situ electrochemical-SPR analyses are used to characterize the bioelectrocatalytic functions of the biomaterial-polymer interface. The current responses of the bioelectrocatalytic system increase as the glucose concentrations are elevated. Similarly, the SPR spectra of the system are controlled by the concentration of glucose. The glucose concentration controls the steady-state concentration ratio of PAn/PAn(2+) in the film composition. Therefore, the SPR spectrum of the film measured upon its electrochemical oxidation is shifted from the spectrum typical for the oxidized PAn(2+) at low glucose concentration to the spectrum characteristic of the reduced PAn at high glucose concentration. Similarly, the polyaniline/poly(acrylic acid) film acts as an electrocatalyst for the oxidation of NADH. Accordingly, an integrated bioelectrocatalytic assembly was constructed on the electrode by the covalent attachment of N(6)-(2-aminoethyl)-beta-nicotinamide adenine dinucleotide (amino-NAD(+), 2) to the polymer film, and the two-dimensional cross-linking of an affinity complex formed between lactate dehydrogenase and the NAD(+)-cofactor units associated with the polymer using glutaric dialdehyde as a cross-linker. In situ electrochemical-SPR measurements are used to characterize the bioelectrocatalytic functions of the system. The amperometric responses of the system increase as the concentrations of lactate are elevated, and an electron-transfer turnover rate of 350 s(-1) between the biocatalyst and the electrode is estimated. As the PAn(2+) oxidizes the NADH units generated by the biocatalyzed oxidation of lactate, the PAn/PAn(2+) steady-state ratio in the film is controlled by the concentration of lactate. Accordingly, the SPR spectrum measured upon electrochemical oxidation of the film is similar to the spectrum of PAn(2+) at low lactate concentration, whereas the SPR spectrum resembles that of PAn at high concentrations of lactate.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ja012680rDOI Listing

Publication Analysis

Top Keywords

polyaniline/polyacrylic acid
16
situ electrochemical-spr
12
glucose concentration
12
spr spectrum
12
film
9
integrated bioelectrocatalytic
8
electrochemical-spr measurements
8
polymer film
8
covalent attachment
8
acid film
8

Similar Publications

This study addressed the limited antibacterial durability of textile materials, which has suppressed their applications in preventing infectious disease transmission. A class of highly durable antibacterial textiles was developed by incorporating protonated polyaniline (PANI) textile with poly(acrylic acid) (PAA) as the functional binder via cross-linking polymerization. The resulting PAA-PANI textile exhibits exceptional electrical conductivity, reaching 8.

View Article and Find Full Text PDF

Rapid-Response and Wide-Range pH Sensors Enabled by Self-Assembled Functional PAni/PAA Layer on No-Core Fiber.

Materials (Basel)

October 2022

National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China.

The measurement of pH has received great attention in diverse fields, such as clinical diagnostics, environmental protection, and food safety. Optical fiber sensors are widely used for pH sensing because of their great advantages. In this work, an optical fiber pH sensor is fabricated, by combining the merits of the multimode interference configuration and pH-sensitive polyaniline/polyacrylic acid (PAni/PAA) coatings, which was successfully in situ deposited on the no-core fiber (NCF) by the layer-by-layer (LBL) self-assembly method.

View Article and Find Full Text PDF

Preparation of a porous composite film for the fabrication of a hydrogen peroxide sensor.

Sensors (Basel)

June 2012

Green Technology Research Center, Department of Chemical and Materials Engineering, Chang Gung University, Tao-Yuan 33302, Taiwan.

A series of dopant-type polyaniline-polyacrylic acid composite (PAn-PAA) films with porous structures were prepared and developed for an enzyme-free hydrogen peroxide (H(2)O(2)) sensor. The composite films were highly electroactive in a neutral environment as compared to polyaniline (PAn). In addition, the carboxyl group of the PAA was found to react with H(2)O(2) to form peroxy acid groups, and the peroxy acid could further oxidize the imine structure of PAn to form N-oxides.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!