A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Laser-activated membrane introduction mass spectrometry for high-throughput evaluation of bulk heterogeneous catalysts. | LitMetric

Laser-activated membrane introduction mass spectrometry (LAMIMS), a high-throughput screening method, evaluates heterogeneous catalysts under realistic reactor conditions. It is a precise, versatile system requiring no moving parts. The catalyst array is supported on carbon paper overlaid upon a silicone rubber membrane configured in a variation of membrane introduction mass spectrometry as introduced by Cooks. The carbon paper serves as a heat-dissipating gas diffusion layer that permits laser heating of catalyst samples far above the decomposition temperature of the polymer membrane that separates the array from the mass spectrometer vacuum chamber. A computer-controlled CO2 bar code writing laser is used for fine-tune heating of the catalyst spots above the base temperature of the LAMIMS reactor. The detailed design and performance of LAMIMS is demonstrated on arrays of "real world" bulk water-gas shift catalysts using natural and isotopically labeled reactor feed streams. A bulk catalyst array spot can be evaluated for activity and selectivity in as little as 1.5 min. All array screening results were confirmed by industrial microreactor evaluations.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac0255577DOI Listing

Publication Analysis

Top Keywords

membrane introduction
12
introduction mass
12
mass spectrometry
12
laser-activated membrane
8
heterogeneous catalysts
8
catalyst array
8
carbon paper
8
heating catalyst
8
mass
4
spectrometry high-throughput
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!