Objectives: To assess the relationship between a broad range of vision functions and measures of physical performance in older adults.
Design: Cross-sectional study.
Setting: Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study.
Participants: Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95.
Measurements: Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance).
Results: The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes.
Conclusions: Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1532-5415.2002.50019.x | DOI Listing |
Int Ophthalmol
January 2025
Department of Ophthalmology, Command Hospital, Pune, 411040, India.
Purpose: This study aimed to evaluate whether the digital eye strain (DES) was associated with the low central corneal thickness (CCT).
Methods: This observational cross-sectional pilot study was conducted from April 2023 to October 2023 at a tertiary eye care centre in North India, where CCT values were compared between subjects with DES and those without DES. Two hundred and eighty subjects (n = 280) aged 15-40 years with clear corneas and lenses were initially included in this study.
Int Ophthalmol
January 2025
Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin, China.
Purpose: To evaluate the efficacy and complications of simplified graded inferior oblique anterior transposition (IOAT) in treating at least 10 PD vertical deviation in the primary position and inferior oblique muscle overaction (IOOA).
Methods: This retrospective study reviewed the medical records of 65 patients treated with simplified graded IOAT procedures for both vertical deviation and IOOA. Patients were grouped according to vertical deviation in the primary position.
Int Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.
Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.
Setting: Peking University Third Hospital, Beijing, China.
Design: Retrospective observation study.
Nat Commun
January 2025
Faculty of Health Sciences, University of Macau, Taipa, Macau SAR, China.
The fabrications of circularly polarized luminescent (CPL) material are mainly based on the chemical and physical strategies. Controlled biosynthesis of CPL-active materials is beset with difficulties due to the lack of bioactive luminescent precursors and bio-reactors. Enlighted by microbe-assisted asymmetric biosynthesis, herein, we show the in situ bacterial fermentation of Komagataeibacter sucrofermentants to fabricate a series of bacterial cellulosic biofilms with CPL of green, orange, red, and near-infrared colors.
View Article and Find Full Text PDFClin Exp Optom
January 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Clinical Relevance: Accommodation is crucial for clear near vision and is predominantly affected by presbyopia. The ability to modulate accommodative function with eye drops could offer a pharmacological approach to manage presbyopia.
Background: To investigate the effects of different concentrations of pilocarpine eye drops on ocular accommodation in young volunteers.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!