A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determinants of coronary artery compliance in subjects with and without angiographic coronary artery disease. | LitMetric

Objectives: The goal of this study was to determine factors contributing to the biomechanical properties of coronary arteries in people with and without angiographic coronary artery disease (CAD).

Background: The stiffness of the aorta is known to increase with increasing age and in the presence of CAD. However, little is known about the mechanics of coronary arteries, which may have important clinical consequences.

Methods: Intravascular ultrasound was used to determine the mechanical properties of coronary arteries and plaque behavior in subjects with CAD (n = 38), those with chest pain but angiographically normal coronary arteries (N) (n = 9) and those early (<2 weeks) after cardiac transplant (T) (n = 14).

Results: Coronary arteries dilated during systole in all groups, but cross-sectional compliance and distensibility were lowest in the proximal left anterior descending artery (LAD) in the subjects with CAD compared with the N and T groups (compliance: 1.2 +/- 0.2 vs. 1.7 +/- 0.5 and 2.7 +/- 0.6 x 10(-2) mm(2) mm Hg(-1) [mean +/- SEM] respectively, p < 0.02 CAD vs. T; distensibility: 0.8 +/- 0.2 vs. 1.7 +/- 0.5 and 1.7 +/- 0.3 x 10(-3) mm Hg(-1), p < 0.05 CAD vs. T). There was extensive plaque in the CAD group, and plaque was also present in the N group, but minimal atheroma was present in the T group. Plaque cross-sectional area diminished significantly during systole in both the LAD and circumflex arteries. Absolute changes were: 0.50 +/- 0.30, 0.33 +/- 0.11 and 0.68 +/- 0.13 mm(2) in the proximal LAD, distal LAD and proximal circumflex arteries, respectively. In subjects with atheroma, there was a significant correlation between cross-sectional compliance and plaque compression at all sites, and plaque compression was a significant determinant of cross-sectional compliance at both proximal sites in multiple regression analyses with age, mean arterial pressure and extent of plaque as the other independent variables.

Conclusions: A major determinant of the systolic increase in coronary luminal area in patients with atheroma is a reduction in plaque cross-sectional area during systole.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0735-1097(02)01842-9DOI Listing

Publication Analysis

Top Keywords

coronary arteries
16
coronary artery
12
angiographic coronary
8
artery disease
8
properties coronary
8
coronary
6
determinants coronary
4
artery compliance
4
compliance subjects
4
subjects angiographic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!