Objective: To demonstrate the feasibility and safety of using functional magnetic resonance imaging (fMRI) to determine the blood oxygen level dependent changes (BOLD) in patients undergoing vagal nerve stimulation (VNS) for the treatment of epilepsy.
Methods: Four patients with an implanted vagus nerve stimulator had fMRI images acquired during several cycles of intermittent VNS. Blood oxygen level dependent changes were detected. These regions were then superimposed upon the patients' structural MR images.
Results: Patients undergoing VNS tolerated fMRI without difficulty. No complications with the implanted stimulators were encountered. Areas of activation were noted in several cortical regions, including frontal, temporal, parietal, and occipital cortices.
Conclusion: Our study in four patients shows fMRI can be performed safely in patients with an implanted vagal nerve stimulator. The successful use of fMRI during VNS offers potential advantages over PET imaging by allowing rapid image acquisition and the ability to repeatedly study patients over time. Our preliminary results differ from previous PET or SPECT studies in failing to detect changes in subcortical areas. This finding could be due to the smaller n in this study compared with the other studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/seiz.2001.0601 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Division of Orthopedic Surgery, Changhua Christian Hospital, Changhua, Taiwan.
Background: Despite advancements in prosthetic designs and surgical techniques, patellar dislocation remains a rare but significant complication following total knee arthroplasty, with an incidence ranging between 0.15% and 0.5%.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Pediatric Orthopedics, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, Hunan, 410013, China.
Backgroud: Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.
Methods: A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024.
J Prosthet Dent
January 2025
Assistant Professor, Restorative and Prosthodontic Department, The Ohio State University College of Dentistry, Columbus, OH.
Statement Of Problem: Although immediate implant loading has shown promising clinical results and high survival rates, an increased risk of implant failure and complications has been reported. Achieving consistently predictable outcomes with this approach remains a challenge, but evidence-based guidelines to assist in selecting suitable patients are lacking.
Purpose: The purpose of this retrospective clinical study was to investigate the success rate, survival rate, and complications of immediate implant loading compared with early and delayed loading.
J Prosthet Dent
January 2025
Assistant Professor, Department of Prosthodontic, College of Dental Medicine, Rangsit University, Phatum Thani, Thailand. Electronic address:
Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.
Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.
Eur Arch Otorhinolaryngol
January 2025
Department of Radiology, Istanbul Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!