A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of source images of computed tomographic angiography to detect the extent of ischemia in hyperacute stroke. | LitMetric

Background And Purpose: Computed tomographic angiography (CTA) is suggested to be a promising tool for patient selection for thrombolytic therapy of acute stroke. It does not only provide information on intracranial vasculature, but also on the capacity of the collateral circulation and the pattern of poorly perfused brain tissue. The objective of our study was to evaluate whether the presence and size of critically hypoperfused tissue assessed with flow positron emission tomography (PET) as a gold standard can reliably be identified on CTA source images.

Methods: Fifteen potential candidates for early thrombolysis underwent CTA 65-170 min (mean 107 min) after the onset of acute anterior circulation stroke. Regional cerebral perfusion was measured between 27 and 86 min (mean 59 min) later with [(15)O]-H(2)O and PET, and the volume of critically hypoperfused cortical tissue was assessed. CTA source images were evaluated by a neuroradiologist and an experienced stroke neurologist. The patients were classified into three groups according to the presumed size of the perfusion deficit on CTA (large, small, no perfusion deficit).

Results: PET revealed the presence of critical cortical hypoperfusion in 10 patients, 5 had no critical cortical hypoperfusion. The neuroradiologist correctly identified the presence of a perfusion deficit in all patients, the neurologist had two false negative and one false positive ratings. Concerning the size of the perfusion deficit, there was considerable inaccuracy in both raters.

Conclusions: The usefulness of CTA source images in yielding information about the perfusion state of stroke patients in clinical routine should not be overestimated.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000057851DOI Listing

Publication Analysis

Top Keywords

source images
12
cta source
12
perfusion deficit
12
computed tomographic
8
tomographic angiography
8
critically hypoperfused
8
tissue assessed
8
size perfusion
8
critical cortical
8
cortical hypoperfusion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!