There has been considerable interest in using safeguarded needles to reduce needlestick injury. In a randomised design, we studied the efficacy and safety of two such needles (the Insyte AutoGuard and the Protective Acuvance), by comparing them with a conventional catheter needle (Insyte), for intravenous cannulation (18 G) in 150 patients and for intra-arterial cannulation in another 150 patients (20 G). For intravenous cannulation, the success rates were similar in the three groups but insertion of the AutoGuard or Acuvance catheter was significantly more difficult than the conventional catheter. For the Acuvance, the back-flow of blood into the chamber was sometimes too slow. For intra-arterial cannulation, insertion of the AutoGuard was significantly more difficult than the other two devices, mainly because the backflow chamber of the AutoGuard was too short so that the chamber often filled with blood before cannulation. Insertion of the Acuvance was significantly more difficult than the conventional catheter. For both intravenous and intra-arterial insertion, handling of the withdrawn needle was judged significantly safer in the AutoGuard group than the other two groups, whereas there was no significant difference in the safety between the Acuvance and conventional groups. In five subjects from the AutoGuard group, blood splashed on retraction of the needle. Blood contamination during needle withdrawal occurred frequently in the control and Acuvance groups, but rarely occurred in the AutoGuard group. Therefore, the AutoGuard needle is more suitable for intravenous cannulation, and the Acuvance is more suitable for intra-arterial cannulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1365-2044.2002.02571.x | DOI Listing |
Expert Rev Med Devices
January 2025
Cardiology Unit, "Card. G. Panico" Hospital, Tricase (Le), Italy.
Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.
View Article and Find Full Text PDFActa Cardiol
January 2025
Department of Cardiovascular Medicine, Yale University School of Medicine, New Haven, CT, USA.
Background: Trans-radial coronary angiogram (TR-CAG) has gained popularity due to lower complication rates compared to transfemoral access. Operators can use either conventional catheters, such as Judkins, or single dedicated catheters, such as Tiger-II. This meta-analysis compared the safety and efficacy of Tiger-II versus Judkins catheters in TR-CAG.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
December 2024
Department of Critical Care Medicine, Provincial Hospital Affiliated to Shandong First Medical University, Jinan 250021, Shandong, China. Corresponding author: Zhang Jicheng, Email:
Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.
Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.
PLoS One
January 2025
Department of Anesthesiology, Chengdu Women's and Children's Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Background: Literature regarding the advantages of HFNC in infants for ensuring oxygen supply after non-cardiac surgery is insufficient. The purpose of our study is to compare COT vs. HFNC on postoperative outcomes in infants undergoing non-cardiac surgery.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Transcatheter mitral valve replacement (TMVR) may emerge as a surgical alternative for high-risk patients with severe mitral annular calcification (MAC), yet several questions remain to be addressed. We present the case of a 67-year-old high-risk female patient with severe MAC (MAC score = 8) and mitral stenosis (effective orifice area = 121.3 mm).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!