Bone traps vary in design, although the effect of pore size on the nature of the debris collected in vivo has not yet been established. The aims of this study were 1) to compare the clinical performance of two bone collectors during implant surgery, ii) to establish the mass of tissue collected by each device, and iii) to characterize the nature of the collected debris. Thirty-eight patients (paired for implant site) were categorised into three clinical groups according to the site and the number of implants they were to receive. Patients underwent bone collection with the Frios bone trap or the Osseous Coagulum Trap according to a randomisation sequence. The samples were fixed in formalin, frozen, freeze-dried and weighed. Material from each sample was embedded in paraffin wax and stained with haematoxylin and eosin. All sections were examined by optical microscopy and the proportion of bone to coagulum was established histomorphometrically. During surgery, the Frios bone trap blocked once and the Osseous Coagulum Trap blocked 11 times. In all cases where blockage occurred, excess coagulum was apparent. All the samples that were collected by the Frios bone trap contained bone and coagulum, with a mean proportion of 90.6% bone. With regard to the Osseous Coagulum Trap, one sample contained no bone and two samples contained only trace amounts of bone; the remaining samples contained a mean proportion of 67.3% bone. Pore size affects both clinical performance and the histological composition of the debris collected, and this might have important implications if used as an augmentation material.

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0501.2002.130310.xDOI Listing

Publication Analysis

Top Keywords

bone
13
frios bone
12
bone trap
12
osseous coagulum
12
coagulum trap
12
implant surgery
8
pore size
8
debris collected
8
clinical performance
8
bone coagulum
8

Similar Publications

Fracture-related infection (FRI) is a serious orthopaedic complication and its diagnosis, particularly in the upper extremity, is difficult and poorly defined in current literature. An international consensus definition of FRI was published in 2018, and our scoping review aims to investigate FRI diagnostic tools reported in the primary literature and their biostatistical utility. A review of articles generated from the PubMed/NCBI search term "fracture-related infection" was undertaken using PRISMA methodology.

View Article and Find Full Text PDF

Chryseobacterium indologenes is a rare human pathogen which is nowadays considered an emerging fearsome organism because of its upcoming antibiotic resistance. We present a quite unique case of a multi drug resistant C. indologenes surgical wound infection in a patient submitted to cannulated screw fixation of a displaced medial malleolus fracture.

View Article and Find Full Text PDF

Chondrosarcomas are the second most common primary bone sarcoma. Due to chondrosarcomas relative resistance to chemotherapy and radiation, surgical treatment has become the mainstay treatment option. The purpose of our study was to understand the proportion of patients in this population who undergo non-operative treatment options secondary to various reasons and analyze the difference in survival as well as patient and cancer specific characteristics between the two groups.

View Article and Find Full Text PDF

Metastasis stands as one of the most prominent prognostic factors in osteosarcoma. Over 70% of metastatic osteosarcoma occurrences affect the lung. Nonetheless, to date, there has been a scarcity of research addressing predictive factors for lung metastasis risk in osteosarcoma.

View Article and Find Full Text PDF

Carbon fibre reinforced polyetheretherketone (CFR-PEEK) implants have gained interest because of reported biomechanical advantages and radio-lucent properties. The aim of this study was to evaluate the role of CFR-PEEK nails in patients with metastatic bone disease (MBD). We performed a retrospective cohort study evaluating patients with MBD undergoing intramedullary (IM) nailing for prophylaxis or fixation of pathological fractures using CFR- PEEK or titanium implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!