Objectives: Obstructive jaundice frequently complicates pancreatic carcinoma and is associated with complications such as malabsorption, coagulopathy, progressive hepatocellular dysfunction, and cholangitis in addition to disabling pruritus, which greatly interferes with terminal patients' quality of life. Endoscopic placement of biliary stents decreases the risk of these complications and is considered the procedure of choice for palliation for patients with unresectable tumors. We used decision analysis with Markov modeling to compare the cost-effectivenesses of plastic stents and metal stents in patients with unresectable pancreatic carcinoma.
Methods: A model of the natural history of unresectable pancreatic carcinoma was constructed using probabilities derived from the literature. Cost estimates were obtained from Medicare reimbursement rates and supplemented by the literature. Two strategies were evaluated: 1) initial endoscopic plastic stent placement and 2) initial endoscopic metal stent placement. We compared total costs and performed cost-effectiveness analysis in these strategies. The outcome measures were quality-adjusted life months. Sensitivity analyses were performed on selected variables.
Results: Our baseline analysis showed that initial plastic stent placement was associated with a total cost of $13,879/patient and 1.799 quality-adjusted life months. Initial placement of a metal stent cost $13,466/patient and conferred 1.832 quality-adjusted life months. Among the variables examined, expected patient survival was demonstrated by sensitivity analyses to have the most influence on the results of the model.
Conclusion: Initial endoscopic placement of a metal stent is a cost-saving strategy compared to initial plastic stent placement, particularly in patients expected to survive longer than 6 months.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1572-0241.2002.05606.x | DOI Listing |
AJNR Am J Neuroradiol
January 2025
From the Department of Radiology (J.L., E.A.B., C.B., J.C., R.K., W.B., D.F.K), and Department of Neurologic Surgery (Y.C.S., R.K., W.B.), Mayo Clinic, Rochester, MN, United States; Department of Stroke Research (J.L.), Vall d'Hebron Research Institute, Barcelona, Spain; From the Global Institute of Future Technology (Y.L.), Shanghai Jiao Tong University, Shanghai, China; Department of Neurointerventional Radiology (J.C.), Bicetre University Hospital, Le Kremlin Bicetre, France.
Background And Purpose: Proximal protection devices, such as TransCarotid Artery Revascularization (TCAR, SilkRoad Medical, Sunnyvale), aim to yield better outcomes in carotid artery stenting (CAS) than distal protection devices by preventing plaque embolization to the brain. However, transfemoral catheters may not fully reverse flow from the external carotid artery (ECA) to the internal carotid artery (ICA). We assess a new balloon-sheath device, Femoral Flow Reversal Access for Carotid Artery Stenting (FFRACAS), for this purpose.
View Article and Find Full Text PDFOpen Heart
January 2025
Department of Cardiac Surgery, University Hospital Erlangen, Erlangen, Bayern, Germany
Background: Aortic coarctation (CoA) is a congenital anomaly leading to upper-body hypertension and lower-body hypotension. Despite surgical or interventional treatment, arterial hypertension may develop and contribute to morbidity and mortality. Conventional blood pressure (BP) measurement methods lack precision for individual diagnoses and therapeutic decisions.
View Article and Find Full Text PDFJ Glaucoma
January 2025
Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore.
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.
View Article and Find Full Text PDFTurk J Gastroenterol
January 2025
Department of Gastroenterology, Harran University Faculty of Medicine, Şanlıurfa, Türkiye.
Background/aims: Endoscopic retrograde cholangiopancreatography (ERCP) is an essential diagnostic and therapeutic method for pancreato-biliary disorders in adults, but its use in pediatric populations remains limited. This study aims to evaluate the indications, technical success, and safety of ERCP in pediatric patients.
Materials And Methods: A retrospective analysis of all ERCP procedures performed on patients under 18 years of age was conducted at 2 tertiary centers in Türkiye (Harran University and Gaziantep University Hospital) during the period between January 2013 and May 2024.
Case Rep Gastrointest Med
January 2025
Gastroenterology and Hepatology Unit, The Canberra Hospital, Australian Capital Territory, Canberra, Australia.
We present a case of an 80-year-old female who presented with chest pain, vomiting and night sweats a few weeks post thoracic endovascular aortic aneurysm repair (TEVAR). A computed tomography (CT) scan demonstrated a type 1B endoleak for which she underwent a repeat TEVAR. Postoperatively, she developed fever, dysphagia, haematemesis and melaena.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!