Articular cartilage has been shown to exhibit large transverse contractions when loaded in tension, suggesting the existence of large values for the Poisson's ratio. Previous studies have suggested that this effect is dependent on amplitude of applied strain, so that a single Poisson's ratio may not be sufficient to describe cartilage behavior. In this study, the Poisson's ratio (v), toe region modulus (Eo), and linear region modulus (E) of human patellar articular cartilage were calculated in simple tension tests from optical analysis of the two-dimensional strain fields at equilibrium. The Poisson's ratio was found to be independent of strain due to the absence of viscoelastic effects during testing. The Poisson's ratio was found to be significantly higher in the surface zone (1.87 +/- 1.11, p<0.01) than in the middle zone (0.62 +/- 0.23), with no significant correlation of v with age of the cartilage. In general, values for Poisson's ratio were greater than 0.5, suggesting cartilage behavior in tension deviates from isotropy. Reported values for the Poisson's ratio of cartilage in compression have been much lower than values measured here in tension, reflecting a mechanical contribution of the collagen fibers to anisotropy in tension but not compression. The toe-region modulus (Eo) was significantly higher in the surface zone (4.51 +/- 2.78 MPa, n=8) compared to the middle zone (2.51 +/- 1.93 MPa, n=10). In addition, the linear-region modulus (E) in the surface zone, but not middle zone (3.42 +/- 2.17 MPa, n=10), was found to correlate with age (R=0.97, p<0.02) with values of surface zone E equal to 23.92 +/- 12.29 MPa (n=5) for subjects under 70 yr of age, and 4.27 +/- 2.89 MPa (n=3) for subjects over 70 yr. Moduli values and trends with depth were consistent with previous studies of human and animal cartilage. From direct measures of two independent material properties, v and E, we calculated a shear modulus, G, which had not been previously reported for cartilage from tensile testing. Calculated values for surface zone G were 3.64 +/- 1.80 MPa for subjects under 70 yr old and 0.96 +/- 0.69 MPa for subjects over 70 yr old, and were significantly higher in the surface zone than in the middle zone (1.10 +/- 0.78 MPa). This study provides an intrinsic measure for the Poisson's ratio of articular cartilage and its dependence on depth which will be important in understanding the nonlinear tension-compression and anisotropic behaviors of articular cartilage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.1449905 | DOI Listing |
Data Brief
February 2025
Université Paris-Saclay, CEA, CNRS, SPEC, 91191 Gif-sur-Yvette, France.
Silicate glasses are commonly used for many important industrial applications. As such, the literature provides a wealth of different structural, physical, thermodynamic and mechanical properties for many different chemical compositions of oxide glasses. However, a frequent limitation to existing datasets is that only one or two material properties can be evaluated for a given sample.
View Article and Find Full Text PDFEur Phys J E Soft Matter
January 2025
Department of Fundamental Physics, Faculty of Physics, Alzahra University, Tehran, 1993891167, Iran.
A liquid drop resting on a soft substrate is numerically simulated as an energy minimization problem. The elastic substrate is modeled as a cubic lattice of mass-springs, to which an energy term controlling the change of volume is associated. The interfacial energy between three phases of solid, liquid, and vapor is also introduced.
View Article and Find Full Text PDFSmall Methods
January 2025
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
Department of Physics, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, People's Republic of China.
Two-dimensional (2D) carbon allotropes, together with their binary and ternary counterparts, have attracted substantial research interest due to their peculiar geometries and properties. Among them, grapheneplus, a derivative of penta-graphene, has been proposed to exhibit unusual mechanical and electronic behaviour. In this work, we perform a comprehensive first-principles study on its isoelectronic and isostructural analogue, a grapheneplus-like BCN (gp-BCN) monolayer.
View Article and Find Full Text PDFSci Rep
January 2025
Heilongjiang Ground Pressure and Gas Control in Deep Mining Key Laboratory, Heilongjiang University of Science and Technology, Harbin, 15002, China.
When underground tunnels in coal mines traverse geological structurally abnormal zones (faults, collapse columns, fractured zones, etc.), excavation-induced unloading leads to instability and failure of the engineering rock mass. Rock masses in fractured zones are in elastic, plastic, and post-peak stress states, and the process of excavation through these zones essentially involves unloading under full stress paths.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!