Purpose: To test the accuracy of a high performance true fast imaging with steady-state precession (TrueFISP) pulse sequence for the assessment of left ventricular (LV) mass in a large animal model on 1.5-T scanners.
Materials And Methods: We imaged dogs (N = 10) on a clinical 1.5-T clinical scanner using electrocardiogram (ECG)-gated TrueFISP. In all animals, contiguous segmented k-space cine images were acquired from base to apex (in-plane resolution 1 x 1 mm(2), slice thickness 5 mm, TR = 4.8 msec, TE = 1.6 msec) during repeated breath-holds. In nine of the 10 animals, single-shot images gated to end-diastole were also acquired from base to apex in a single breath-hold (in-plane resolution 1 x 1 mm(2), slice thickness 5 mm, TR = 3.2 msec, TE = 1.6 msec). After imaging, animals were killed, the left ventricle was isolated, and the true mass of the left ventricle (free wall and septum) was determined. Independently, two observers blinded to the post-mortem results computed LV masses based on analysis of the magnetic resonance (MR) images.
Results: Comparison of the computed LV mass using TrueFISP to the actual mass showed excellent agreement. Cine-systole was the most accurate technique (mass = 98.6% +/- 4.5% actual, bias = 1.2 +/- 3.4 g) followed by cine-diastole (mass = 97.9% +/- 5.3% actual, bias = 1.8 +/- 4.1 g) and single shot (mass = 94.7% +/- 7.9% actual, bias = 4.2 +/- 6.3 g). Inter- and intra-observer variabilities were low (5.8% +/- 7.1% and 0.4% +/- 4.8%, respectively).
Conclusion: We conclude that TrueFISP imaging is an accurate, rapid method to determine ventricular mass. In single-shot mode, TrueFISP requires only one breath-hold to estimate the mass of the heart within 6% of the actual value, whereas the segmented k-space implementation measured LV mass to within 3% of the true value.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmri.10107 | DOI Listing |
J Clin Med
January 2025
Division of Cardiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
Extracellular volume (ECV) by cardiovascular magnetic resonance (CMR) imaging is associated with disease burden and clinical outcomes. Recent studies in patients with valvular heart disease (VHD) have suggested that the indexed total ECV (iECV) = ECVx(LV/1.05)/body surface area may supersede ECV in terms of prognostication.
View Article and Find Full Text PDFHealthcare (Basel)
January 2025
Faculty of Medicine, Physical Medicine and Rehabilitation, Ondokuz Mayis University, 55270 Samsun, Turkey.
This study aimed to examine the effects of endurance and high-intensity resistance training on arterial stiffness and ventricular repolarization in elite athletes. A total of 50 male athletes from different sports disciplines (volleyball, football, judo, and wrestling) and a sedentary group of 30 males participated in this study. Data collected from all participants included age, height, body weight, cardiovascular hemodynamic parameters, arterial stiffness parameters, and ECG measurements.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Department of Electrocardiology, Institute of Cardiology, Faculty of Medicine, Jagiellonian University Medical College, 31-008 Kraków, Poland.
Cardiac magnetic resonance (CMR) allows for analysis of cardiac function and myocardial tissue characterization. Increased left ventricular mass (LVM) is an independent predictor of cardiovascular events; however, the diagnosis of left ventricular hypertrophy and its prognostic value strongly depend on the LVM indexation method. Evaluation of the quantity and distribution of late gadolinium enhancement assists in clinical decisions on diagnosis, cardiovascular assessment, and interventions, including the placement of cardiac implantable electronic devices and the choice of an optimal procedural approach.
View Article and Find Full Text PDFChin J Nat Med
January 2025
Jiangsu Key Laboratory of TCM Evaluation and Translational Research, Research Center for Traceability and Standardization of TCMs, School of Traditional Chinese Pharmacy, China Pharmaceutical University, Nanjing 211198, China. Electronic address:
Astragali Radix (AR) and Notoginseng Radix et Rhizoma (NR) are frequently employed in cardiovascular disease treatment. However, the efficacy of the AR-NR medicine pair (AN) in improving cardiac remodeling and its underlying mechanism remains unclear. This study aimed to evaluate AN's cardioprotective effect and potential mechanism on cardiac remodeling using transverse aortic constriction (TAC) in mice and angiotensin II (Ang II)-induced neonatal rat cardiomyocytes (NRCMs) and fibroblasts in vitro.
View Article and Find Full Text PDFJ Electrocardiol
January 2025
University of Rochester School of Nursing, NY, USA; University of Rochester Medical Center, NY, USA.
Background: Identifying patients with low left ventricular ejection fraction (LVEF) in the emergency department using an electrocardiogram (ECG) may optimize acute heart failure (AHF) management. We aimed to assess the efficacy of 527 automated 12‑lead ECG features for estimating LVEF among patients with AHF.
Method: Medical records of patients >18 years old and AHF-related ICD codes, demographics, LVEF %, comorbidities, and medication were analyzed.