Mexiletine related chronic defibrillation threshold elevation: case report and review of the literature.

Pacing Clin Electrophysiol

Cardiology Department, Cardiac Research Center, Soroka University Medical Center and Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheva, Israel.

Published: April 2002

Many antiarrhythmic drugs may produce a rise in defibrillation threshold. Mexiletine is a frequently used antiarrhythmic drug in patients with an implantable cardioverter defibrillator, usually thought of as producing no or minimal effects on the defibrillation threshold. The current case report presents a patient with an endocardial implantable cardioverter defibrillator being treated with mexiletine, which precluded the ability to defibrillate the patient.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1460-9592.2002.00507.xDOI Listing

Publication Analysis

Top Keywords

defibrillation threshold
12
case report
8
implantable cardioverter
8
cardioverter defibrillator
8
mexiletine chronic
4
chronic defibrillation
4
threshold elevation
4
elevation case
4
report review
4
review literature
4

Similar Publications

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

Background: In arrhythmogenic cardiomyopathy (ACM), left ventricle-dominant presentation has poorer outcomes than right-dominant presentation, suggesting that interventricular functional disparity might play a role in patients' prognosis. However, the prognostic impact of ventricular functional discordance in ACM patients remains unknown.

Purpose: To assess whether ventricular functional disparity measured as ventricular discordance index, defined as the ratio of right-ventricular ejection fraction (RVEF) to left-ventricular ejection fraction (LVEF), might reveal prognostic disparities between phenotypes and offer added risk stratification value.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Background: Cardiac sarcoidosis involves a significant but difficult-to-define risk of sudden cardiac death (SCD). Current guidelines recommend consideration of an implantable cardioverter defibrillator for patients with extensive or significant myocardial late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging. However, extensive/significant LGE is not defined.

View Article and Find Full Text PDF

Unlabelled: New cardiac implantable electronic devices (CIEDs), such as leadless pacemakers and subcutaneous implantable cardioverter defibrillators (S-ICDs), are being used in patients with adult congenital heart disease. The selection of CIEDs often requires careful consideration due to technical challenges posed by a unique heart structure. A 27-year-old man following a surgical tetralogy of Fallot (TOF) repair developed non-sustained ventricular tachycardia, sick sinus syndrome, and complete atrioventricular block.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!