The purpose of the present investigation was to examine the velocity-related patterns of peak torque (PT), mean power output (MP), mechanomyographic (MMG) amplitude, and electromyographic (EMG) amplitude of the vastus lateralis (VL) muscle in men and women during maximal, eccentric isokinetic muscle actions of the leg extensors. Eight women [mean (SD)] [aged 23 (3) years] and seven men [aged 23 (2) years] volunteered for this investigation. Their PT was measured on a calibrated dynamometer at randomly ordered velocities of 30, 90, and 150 degrees x s(-1). A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes (Ag-AgCl) over the VL muscle. Their MP was determined using the dynamometer software. The results indicated no sex-related differences (P > 0.05) for the patterns of PT, MP, MMG amplitude, or EMG amplitude across velocity. The normalized values for MP and MMG amplitude increased (P<0.05) from 30 to 150 degrees x s(-1) (30 degrees x s(-1) <90 degrees x s(-1) < 150 degrees x s(-1)), while PT and EMG amplitudes remained unchanged across velocity. The results indicated close associations between the velocity-related patterns of MP and MMG amplitudes as well as PT and EMG amplitudes. Thus, MMG amplitude reflected the velocity-related changes in muscle power output, but not torque production, while EMG amplitude reflected torque production, but not muscle power output. During maximal, eccentric isokinetic muscle actions, EMG and MMG signals provided unique information regarding the electrical and mechanical aspects of muscle strength and power.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00421-001-0529-5 | DOI Listing |
Biomed Tech (Berl)
September 2024
Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.
Mechanomyography (MMG) may be used to quantify very small motor responses resulting from muscle activation, voluntary or involuntary. The purpose of this study was to investigate the MMG mean peak amplitude (MPA) and area under the curve (AUC) and the corresponding mechanical responses following delivery of transcranial magnetic stimulation (TMS) to the knee extensors. Fourteen adults (23 ± 1 years) received single TMS pulses at intensities from 30-80 % maximum stimulator output to elicit muscle responses in the relaxed knee extensors while seated.
View Article and Find Full Text PDFPhysiol Meas
September 2024
Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, AR, United States of America.
Levator ani muscles undergo significant stretching and micro-trauma at childbirth. The goal was to assess the neuromuscular integrity of this muscle group by means of magnetomyography (MMG) and correlate with Brink score-a commonly used digital assessment of pelvic floor muscle strength.Non-invasive MMG data was collected on 22 pregnant women during rest and voluntary contraction of the pelvic-floor muscles (Kegels).
View Article and Find Full Text PDFSensors (Basel)
August 2024
Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná, Curitiba 80215-901, PR, Brazil.
(1) Background: The Modified Ashworth Scale (MAS) is commonly used clinically to evaluate spasticity, but its qualitative nature introduces subjectivity. We propose a novel metric scale to quantitatively measure spasticity using mechanomyography (MMG) to mitigate these subjective effects. (2) Methods: The flexor and extensor muscles of knee and elbow joints were assessed with the Modified Ashworth Scale (MAS) during the acquisition of mechanomyography (MMG) data.
View Article and Find Full Text PDFJ Strength Cond Res
August 2024
Department of Kinesiology and Health Promotion, The University of Kentucky, Lexington, Kentucky.
Kwak, M, Succi, PJ, Benitez, B, Mitchinson, C, Samaan, MA, Abel, MG, and Bergstrom, HC. Comparison of force, neuromuscular, and metabolic responses during sustained, isometric handgrip holds to failure anchored to low and high perceptual intensities in men: An exploratory study. J Strength Cond Res 38(8): e405-e416, 2024-This study examined the responses of force alterations, relative to critical force (CF), neuromuscular parameters, and muscle oxygenation (SmO2) for isometric handgrip holds to failure (HTF) anchored to ratings of perceived exertion (RPE) of 3 and 7.
View Article and Find Full Text PDFPhysiol Meas
September 2024
The School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, People's Republic of China.
. The measurement of electromyography (EMG) signals with needle electrodes is widely used in clinical settings for diagnosing neuromuscular diseases. Patients experience pain during needle EMG testing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!