Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study investigated the safety and feasibility of transvenous biventricular defibrillation in ICD patients. Some patients may have high DFTs due to weak shock field intensity on the LV. Animal studies showed a LV shocking electrode dramatically lowered DFTs. This approach might benefit heart failure patients already receiving a LV lead or conventional ICD patients with high DFTs. A modified guidewire was used as a temporary left venous access defibrillation electrode (LVA lead). In 24 patients receiving an ICD, the LVA lead was advanced through a guide catheter in the coronary sinus (CS) and into a randomized LV vein (anterior or posterior) using a venogram for guidance. Paired DFT testing compared a standard right ventricular defibrillation system to a biventricular defibrillation system. There were no complications or adverse events. As randomized, LVA lead insertion success was 87% and 71% for anterior and posterior veins, respectively, and 100% after crossover. Total insertion process time included venogram time (32.5 +/- 26.9 minutes, range 5-115, mode 15 minutes) and LVA lead insertion time (15 +/- 14 minutes, range 1-51, mode 7 minutes). An apical LVA lead position was achieved in 11 (45%) of 24 patients and 7 (64 %) of these 11 displayed a DFT reduction; however, mean DFTs were not statistically different. Transvenous biventricular defibrillation is feasible and was safe under the conditions tested. Additional clinical studies are justified to determine if optimized LV lead designs, lead placement, and shock configurations can yield the same large DFT reductions as observed in animals.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1460-9592.2002.00324.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!