A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nosocomial infections in left ventricular assist device recipients. | LitMetric

Nosocomial infections in left ventricular assist device recipients.

Clin Infect Dis

Department of Internal Medicine, Division of Infectious Diseases, University of Michigan Health System, Ann Arbor, MI, 48109, USA.

Published: May 2002

AI Article Synopsis

  • Infection is a significant risk for patients with left ventricular assist devices (LVADs), with a cohort study revealing a high incidence of various infections among 35 patients over a 3-year period.
  • Out of 36 implanted LVADs, 16 patients experienced surgical site infections, alongside cases of pneumonia, venous infections, and bloodstream infections.
  • The study highlights the need for further research into preventive measures against infections in LVAD recipients, particularly given the trending emergence of antibiotic-resistant organisms.

Article Abstract

Infection remains a serious complication of left ventricular assist device (LVAD) implantation. We performed a cohort study to assess infections among patients who underwent LVAD implantation from October 1996 through May 1999. Thirty-six LVADs were implanted in 35 patients; the mean duration (+/- standard deviation) of LVAD use was 73+/-60 days (total for all patients, 2565 days). Sixteen patients developed surgical site infections (SSIs; rate, 6.2 infections per 1000 LVAD days); 9 were deep-tissue or organ/space infections and 7 were superficial. Other infections included 7 cases of pneumonia (rate, 2.7 cases per 1000 LVAD days), 6 venous infections (rate, 2.3 per 1000 LVAD days), 2 bloodstream infections (rate, cases 0.8 per 1000 LVAD days), 3 urinary tract infections, and 2 skin and soft-tissue infections. Deep SSIs were associated with the requirement for postoperative hemodialysis (P=.02). Overall use of antibiotics was extensive, and a trend toward infection with antibiotic-resistant organisms was noted. Infections were a frequent complication of LVAD implantation. Further studies of interventions for preventing infection in LVAD recipients are warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1086/340052DOI Listing

Publication Analysis

Top Keywords

1000 lvad
16
lvad days
16
lvad implantation
12
infections
10
lvad
9
left ventricular
8
ventricular assist
8
assist device
8
rate cases
8
cases 1000
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!