TRICKS is an acquisition and reconstruction method capable of generating 3D time-resolved angiograms. Arguably, the main problem with TRICKS is the way it handles the outer regions of the k-space matrix, leading to artifacts at the edges of blood vessels. An alternative to the data- processing stage of TRICKS, designed to better represent edges and small vessels, is presented here. A weakness of the new approach is an increased sensitivity to motion compared to TRICKS. Since this method can use the same data as TRICKS, a hybrid reconstruction method could conceivably be developed where the advantages of both approaches are combined. Magn Reson Med 47:1022-1025, 2002.