We compared the outcome of the self-expanding Radius stent and the balloon-expandable Multilink stent serially by angiography and intravascular ultrasound. Successful stent deployment was achieved in 66 lesions of 56 stable angina patients (34 lesions with Radius stents and 32 lesions with Multilink stents). At follow-up, there were no significant differences in minimal lumen diameter or percent diameter stenosis between the groups, nor in restenosis rates, although the Radius stent group rate was slightly lower (23.5% vs. 31.3%). In the Radius stent group, stent cross-sectional area (CSA) increased gradually after implantation until the 6-month follow-up (8.37 +/- 1.83 to 10.16 +/- 2.59 mm(2); n = 15), giving a larger CSA (P = 0.03) than the Multilink stent group, which decreased (9.00 +/- 2.05 to 8.27 +/- 2.15 mm(2); n = 17). The lumen CSA was also slightly larger (6.82 +/- 3.06 vs. 5.84 +/- 1.85 mm(2); P = 0.29) in the Radius stent group. These findings indicated that the Radius stent enlarged progressively after implantation, which might be useful for prevention of restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.10165DOI Listing

Publication Analysis

Top Keywords

radius stent
24
stent group
16
multilink stent
12
stent
11
self-expanding radius
8
stent balloon-expandable
8
balloon-expandable multilink
8
intravascular ultrasound
8
radius
7
+/-
6

Similar Publications

Purpose: To report interim results of the VENICE study, a multi-center, randomized, controlled trial (RCT) comparing STREAMLINE Surgical System (STREAMLINE) canaloplasty with iStent inject W (iStent W) implantation in patients with mild-to-moderate primary open-angle glaucoma (POAG) undergoing phacoemulsification.

Patients And Methods: Safety and efficacy analyses involving the first 72 randomized eyes are included in this report. Following pre- (Screening) and post-medication washout (Eligibility) visits, one eye per subject was randomized 1:1 to STREAMLINE or iStent W after undergoing uncomplicated phacoemulsification.

View Article and Find Full Text PDF

The goal of this work was to develop a general blueprint for a semi-automated image processing tool (SIPT) to measure small, complex features of stent prototypes that can replace the current gold standard of manual measurements. The stents were designed using CAD software and manufactured via laser cutting. Stent prototypes were imaged using a Keyence microscope in top and side view orientations.

View Article and Find Full Text PDF

Dynamics of energy transport on hydromagnetic Casson slippery nanoflow over curved surface.

Heliyon

May 2024

Department of Mathematics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, Tamilnadu, 632014, India.

The study of fluid flow over curved surfaces is crucial in various engineering applications, such as designing aircraft wings, turbines, and submarines. Curved surfaces are being explored in various biomedical applications, such as designing stents for blood vessels and implants for bones and joints. Concerning the present applications of curved stretching sheets on fluid dynamics along with trihybrid nanofluids, this study is unique and fills the research gaps and offers solutions to several issues.

View Article and Find Full Text PDF

Audience: The targeted audience for this simulation is Emergency Medicine (EM) residents. Medical students, advanced practice providers, and staff physicians could all also find educational merit in this scenario.

Background: Cardiovascular disease is the leading cause of death in the United States according to the CDC.

View Article and Find Full Text PDF

Micro-injection molding (MiM) is a promising technique for manufacturing biodegradable polymeric vascular stents (BPVSs) at scale, in which a trapezoidal strut cross section is needed to ensure high-quality de-molding. However, there is a lack of research on the influence of the strut cross-sectional shape on its mechanical properties, posing a challenge in determining the key geometries of the strut when using MiM to produce BPVSs. Hence, this work has investigated the relationships between the geometry parameters, including the de-molding angle, and the radial support property of BPVSs using the finite element method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!