A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cardiac contractility modulation by electric currents applied during the refractory period. | LitMetric

Cardiac contractility modulation by electric currents applied during the refractory period.

Am J Physiol Heart Circ Physiol

Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, New York 10032, USA.

Published: May 2002

Inotropic effects of electric currents applied during the refractory period have been reported in cardiac muscle in vitro using voltage-clamp techniques. We investigated how electric currents modulate cardiac contractility in normal canine hearts in vivo. Six dogs were instrumented to measure regional segment length, ventricular volume (sonomicrometry), and ventricular pressure. Cardiac contractility modulating (CCM) electric currents (biphasic square pulses, amplitude +/-20 mA, total duration 30 ms) were delivered during the refractory period between pairs of electrodes placed on anterior and posterior walls. CCM significantly increased index of global contractility (E(es)) from 5.9 +/- 2.9 to 8.3 +/- 4.6 mmHg/ml with anterior CCM, from 5.3 +/- 1.8 to 8.9 +/- 4.0 mmHg/ml with posterior CCM, and from 6.1 +/- 2.6 to 11.0 +/- 7.0 mmHg/ml with combined CCM (P < 0.01, no significant change in volume axis intercept). End-systolic pressure-segment length relations showed contractility enhancement near CCM delivery sites, but not remotely. Relaxation was not influenced. CCM increased mean aortic pressure, but did not change peripheral resistance. Locally applied electrical currents enhanced global cardiac contractility via regional changes in myocardial contractility without impairing relaxation in situ.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.00959.2001DOI Listing

Publication Analysis

Top Keywords

cardiac contractility
16
electric currents
16
refractory period
12
+/- mmhg/ml
12
currents applied
8
applied refractory
8
ccm increased
8
+/- +/-
8
ccm +/-
8
ccm
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!